11
STEP 8S – Select the time for the fourth cycle (which in this example is RINSE) using
the or button. Press NEXT to go to Step 9S. Press REGEN to return to the
previous step.
STEP 9S - Set Grain Capacity using the or button. The ion exchange capacity
is in grains of hardness as calcium carbonate for the system based on the pounds of
salt that will be used. Calculate the pounds of salt using the fill time previously
selected. The allowable grains capacity range varies from 5,000 to 200,000 grains.
The increment increase is 500 for the range from 5000 to 30,000; 1000 for the range
of 30,000 to 100,000; and 2000 for the range of 100,000 to 200,000. Grains capacity
is affected by the fill time. The grains capacity for the selected fill time should be
confirmed by testing. The capacity and hardness levels entered are used to automati-
cally calculate reserve capacity when gallon capacity is set to AUTO. Press NEXT to
go to Step 10S. Press REGEN to return to previous step.
STEP 10S – set Gallons Capacity using or button. If value is set to:
• “AUTO” gallon capacity will be automatically calculated and reserve capacity will be
automatically estimated;
• “oFF” regeneration will be based solely on the day override set (see Installer Dis-
play/Settings Step 3I); or
• as a number (allowable range 20 to 50,000) regeneration initiation will be based off
the value specified.
Increment increase is 20 for the range 20 to 1000, 50 for the range of 1000 to 10,000
and 100 for the range of 10,000 to 50,000.
If “oFF” or a number is used, hardness display will not be allowed to be set in Installer
Displays/Settings Step 2I. See Table 8 for more detail. Press NEXT to go to Step
11S. Press REGEN to return to previous step.
STEP 11S – Set Regeneration Time Options using the or button. If value is set
to:
• “NORMAL” means regeneration will occur at the preset time;
• “on O” means regeneration will occur immediately when the gallons capacity
reaches 0 (zero); or
• “NORMAL + on 0” means regeneration will occur at one of the following:
- the preset time when the gallons capacity falls below the reserve or the specified
number of days between regenerations is reached, whichever comes first; or
- immediately after 10 minutes of no w ater usage when the gallon capacity reaches 0 (zero).
See page 23 for more options. Press NEXT to go to Step 12S. Press REGEN to
return to previous step.
STEP 12S – Set Low Salt Warning using the or button. If value is set to:
• “oFF” no low salt level warning will appear for the user,
or
• a specific value “FILL SALT” will flash on the display
when the calculated remaining pounds of salt falls below
that level. Allowable values range from 10 to 400 pounds
in 10 pound increments.
Press NEXT to exit Softener System Setup. Press
REGEN to return to previous step.
STEP 11S
STEP 9S
STEP 12S
Figure 12b
STEP 8S
RINSE
STEP 10S