Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using or buttons. AM/
PM toggles after 12. Press NEXT to go to step 3.
Step 3 - Current Time (minutes): Set the minutes of day using or buttons.
Press NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss - If the power goes out for less than two hours, the system will
automatically reset itself. If an extended power outage occurs, the time of day
will flash on and off which indicates the time of day should be reset. The system
will remember the rest of the program settings. Do not forget to reset for daylight
savings time.
SET TIME OF DAY
Figure 9
STEP 1
STEP 3
STEP 2
INSTALLER DISPLAYS/SETTINGS
Step 1 - Press NEXT and simultaneously for 3 seconds.
Step 2 - Hardness: Set the amount of total compensated hardness in grains (hardness as
calcium carbonate) per gallon using or buttons. The default is 20 with value ranges from 1 to
150 in 1 grain increments. Note: The grains per gallon should be increased if soluble iron needs
to be reduced. Add 3 grains of hardness for each ppm of iron present. If this display shows nA -
, then system is either set-up in “time clock” or “filter” modes. (See page 23). Press NEXT to go to
Step 3. Press REGEN to exit Insta ller Dis plays/S ettings.
Step 3 - Day Override: This sets the number of days between regenerations. If value set to
“oFF” regeneration initiation is based solely on gallons used. If value is set as a number (allow-
able range from 1 to 28) a regeneration initiation will be called for on that day even if sufficient
number of gallons were not used to call for a regeneration. Set Day Override using or
buttons:
• number of days between regeneration (1 to 28); or
• “oFF”
See figure 12a & b, page 10-11, for more detail on softener setup. Press NEXT to go to step 4.
Press REGEN to return to previous step.
Step 4 - Next Regeneration Time (hour): Set the hour of day for regeneration using or
buttons. AM/PM toggles after 12. The default time is 2:00 a.m. This display will show “REGEN”
on 0 GAL if system is set for immediate regeneration. See table 6, page 19. Press NEXT to go to
step 5. Press REGEN to return to previous step.
Step 5 - Next Regeneration Time (minutes): Set the minutes of day for regeneration using or
buttons. This display will not be shown if system is set for immediate regeneration. Press
NEXT to exit Installer Displays/Settings. Press REGEN to return to previous step.
Figure 10a
STEP 1
STEP 2
STEP 5
STEP 4
STEP 3

RETURN TO
NORMAL MODE