Henny Penny 561 technical manual Error Codes, Display, Cause, Panel Board Correction

Models: 561

1 3
Download 3 pages 16.03 Kb
Page 2
Image 2
4-2. ERROR CODES

 

 

Model 500/561/600

4-2. ERROR CODES

In the event of a control system failure, the digital

 

 

display will show an “Error Message.” These

 

 

messages are coded: “E4”, “E5”, “E6”, “E10”,

 

 

“E15”, “E20”, “E31”, “E41”, “E46”, “E54”, and

 

 

E-70-A & B. A constant tone is heard when an

 

 

error code is displayed, and to silence this tone,

 

 

press any button.

 

 

 

 

DISPLAY

CAUSE

PANEL BOARD CORRECTION

 

“E-4”

Control board

Turn switch to OFF position, then turn switch back to

 

 

overheating

ON; if display shows “E-4”, the control board is getting

 

 

 

too hot; check the louvers on each side of the unit for

 

 

 

obstructions

 

 

 

 

 

“E-5”

Shortening

Turn switch to OFF position, then turn switch back to ON;

 

 

overheating

if display shows “E-5”, the heating circuits and temperature

 

 

 

probe should be checked

 

 

 

 

 

“E-6A”

Temperature

Turn switch to OFF position, then turn switch back to ON;

 

 

probe open

if display shows “E-6”, check the temperature probe;

 

 

 

to replace, refer to Technical Manual

 

 

 

 

 

“E-6 B”

Temperature

Turn switch to OFF position, then turn switch back to ON;

 

 

probe shorted

if display shows “E-6” check the temperature probe;

 

 

 

to replace, refer to Technical Manual

 

 

 

 

 

“E-10”

Highlimit

Reset the high limit by manually pushing up on the reset

 

 

 

button; if high limit does not reset, high limit must be

 

 

 

replaced; refer to Technical Manual

 

 

 

 

 

“E-15”

Drain switch

Close drain, using the drain valve handle; if display still

 

 

failure

shows “E-15”, check the drain microswitch; refer to

 

 

 

Technical Manual

 

 

 

 

 