Henny Penny BCF-24/65/110 Condensation, Bend out the clips securing the rodent cover on the back

Models: BCF-24/65/110 BCM-110

1 14
Download 14 pages 39.48 Kb
Page 7
Image 7

 

Model BCF-24/65/110, BCM-110

2-13. CONDENSATION

2. Bend out the clips securing the rodent cover on the back of

EVAPORATOR (Continued)

the unit, and pull the cover down.

3.Disconnect the wires to the evaporator.

4.Pull up on the bottom of the evaporator to disengage the evaporator from the bracket. The evaporator is snapped into place. No hardware is securing it.

5.Replace evaporator in reverse order.

2-14. DOOR SEAL

1. Open door and pull out on a corner of the seal until seal

 

clears the retainer.

2.Continue around the door, pulling the seal from the door.

3.Install new seal, starting with the four corners first.

603

2-7

Page 7
Image 7
Henny Penny BCF-24/65/110, BCM-110 manual Condensation, Bend out the clips securing the rodent cover on the back