Model BCF-24/65/110, BCM-110

2-15. RUN CAPACITOR

1. Remove the electrical power to the unit.

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit breaker,

 

 

or unplug cord at wall receptacle.

 

2.

Remove the two screws securing the front panel and pull

 

 

down the panel.

Run Capacitor

3.

Bend out the clips securing the rodent cover on the back of

 

 

the unit, and pull the cover down.

 

4.

Using a Phillips head screwdriver, remove the two screws

 

 

securing the cover of the junction box, and remove the cover.

 

5.

Disconnect the wires from the relay to the capacitor.

 

6.

Remove the capacitor from the unit, from the front.

 

7.

Install new capacitor in reverse order.

2-16. START CAPACITOR AND

1.

Remove the electrical power to the unit.

START RELAY

 

 

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Bend out the clips securing the rodent cover on the back of the unit, and pull the cover down.

3.Using a Phillips head screwdriver, remove the two screws securing the cover of the junction box, and remove the cover. (See section 2-12 above).

Start Relay

Start Capacitor

4.Disconnect the wires to either the relay or the capacitor, and remove component from the unit.

5.Install new component in reverse order.

2-8