Model BCF-24/65/110, BCM-110

2-6. BUZZER

1. Remove the electrical power to the unit.

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit breaker,

 

 

or unplug cord at wall receptacle.

 

2.

Using a Phillips head screwdriver, remove the two screws

 

 

securing the front panel, and lower the panel.

 

3.

Remove the two bolts (under unit) securing the control box.

 

4.

Pull the box from the front of the unit.

 

5.

Remove the four screws securing the control box top and

 

 

pull the top from the box.

 

6.

Label and remove the wires to the buzzer.

 

7.

Remove the two screws securing the buzzer to the bracket

 

 

and remove the buzzer from the bracket.

 

8.

Install new buzzer in reverse order.

2-7. CONTACTOR

1.

Remove the electrical power to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Follow steps 2 through 5 in the Control Board Section.

3.Using a flathead screwdriver, remove the two screws securing the bracket to the box, and remove the bracket.

4.Label and remove the wires from the contactor.

5.Slide the contactor off the retainer.

6.Install new contactor in reverse order.

603

2-3

Page 3
Image 3
Henny Penny BCF-24/65/110, BCM-110 manual Contactor