Model BCF-24/65/110, BCM-110

2-10. AIR PROBE AND

1. Remove the electrical power to the unit.

EVAPORATOR PROBE

 

 

 

To avoid electrical shock or property damage, move the

 

 

power switch to OFF and disconnect main circuit breaker,

 

 

or unplug cord at wall receptacle.

 

2.

Using a Phillips head screwdriver, remove the two screws

 

 

securing the evaporator door, and pull out on the door.

 

3.

Remove the appropriate probe from the bracket. (See photo

Air Probe

Evaporator

at left).

Probe

4.Remove the control box from the unit, following steps 2 through 5 in the Control Board Section.

5.Find the appropriate wires to the PC board and remove the wires from the board.

6.Pull the probe wire through the wiring harness.

7.Install new probe in reverse order.

2-11. FRIGIPROBE

1. Remove the electrical power to the unit.

To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.

2.Using a Phillips head screwdriver, remove the two screws securing the evaporator door, and pull out on the door.

3.Remove the control box from the unit, following steps 2 through 5 in the Control Board Section.

4.Find the appropriate wires to the PC board and remove the wires from the board.

Frigiprobe

5.Pull the probe wire through the wiring harness.

6.Install new probe in reverse order.

603

2-5

Page 5
Image 5