SECTION 3. OPERATION

Model CBC/CBR-103,104,105,106,107

SECTION 3. OPERATION

3-1. INTRODUCTIONThis section provides explanations of all controls, along with operating procedures and daily maintenance. Read the Introduction, Installation and Operation Sections before operating the unit.

 

 

 

Wait at least 4 hours before plugging the unit into an

 

 

 

electrical supply. The gases and oils in the refrigeration

 

 

 

system need to settle before operating the compressor, or

 

 

 

damage to the compressor could result.

 

 

3-2.

OPERATING CONTROLS

Refer to figure 3-1.

 

 

 

Fig.

Item

Description

Function

 

 

 

No.

No.

 

 

 

 

 

3-1

1

Power Switch

A rocker switch that turns electrical power off and on to

 

 

 

the unit; located on the bottom of the control panel

 

3-1

2

DigitalDisplay

Shows the temperatures and the information in the Technical

 

 

 

Mode

 

 

 

3-1

3

 

The up and defrost button is used to increase setpoint

 

 

 

values, as well as programming values; also, automatic

 

 

 

defrost cycles are programmed in the controls, but to

 

 

 

 

manually start a defrost cycle, press and hold

for 3

 

 

 

seconds to start a manual defrost cycle

 

 

 

 

 

(“DEF/SET’ shows in display)

 

 

 

3-1

4

 

The down button is used to decrease setpoint values, as

 

 

 

well as programming values

 

 

 

3-1

5

 

Press the set button to view the setpoint temperature, or

 

 

 

hold it for it for 4 seconds to enter the Program Mode;

 

 

 

once in the Program Mode, press

to view other

 

 

 

parameter setpoints; press

, along with

and

 

 

 

to change the parameters.

 

 

 