| Model |
dS: (defrost system (computation)) dF=digifrost feature; | |
Continued | defrost start time based on total compressor running time. |
rt=real time; defrost start frequency, based on real time
dI: (defrost interval) defrost frequency in hours, based on the selection of “dS”
dE: (defrost endurance) total (maximum) length of a defrost cycle, expressed in minutes. (1...99 range)
dL: (display lock) temperature display is locked during a defrost cycle. (0...31 range)
“n”=no (readout continues to display the actual tempera- ture, even during a defrost cycle
“y”=yes (readout is locked)
dr: (display
locked and does not change during this cycle “dF”=during the defrost “dF” is displayed
do: (defrost at power on) selects whether or not, the system goes through the defrost cycle at
“n”=no
“y”=yes
dd:(defrost delay at power on) delay of defrost cycle, in minutes. (0...99 range)
Error Code “E1”
This is the only error code in these controls. It indicates a tempera- ture sensor failure, such as, a shorted sensor, a sensor break, or absence of sensor.
It can also indicate an
In case of an