BULB SOCKET
ASSEMBLY (3)
BLK
WHT
| EMBER LIGHT |
| CONNECTOR BLOCK |
WHT | BLK |
| WHT |
BLK
Figure 12.3 Ember Light Connector Block Detail
F. Install the Flame Solenoid
•Remove the screw and knob from the variable regulator and discard.
•Remove the nut from the regulator and discard.
•Remove the bag containing a washer and blue and red plungers from the side of the flame control solenoid.
•Place washer on flame control solenoid.
•Insert the correct plunger (blue - natural gas, red - propane) into the flame control solenoid.
•Thread the flame control solenoid with correct plunger into the thread hole in the variable regulator. Turn into valve approximately two full turns. Do not tighten or damage may occur.
•Connect orange wires from control box to the flame control solenoid.
G.Connect the Temperature Sensor Switch for Fan (optional)
•Find the two yellow wires from the
•Connect one yellow wire to one jumper wire hanging from the thermodisc.
•Connect the other yellow wire to remaining jumper wire hanging from thermodisc.
•See Figure 12.2 for wiring diagram.
GAS CONTROL
VALVE
WASHER
VARIABLE
REGULATOR
VARIABLE
REGULATOR
KNOB
SCREW
NUT
WASHER
FLAME CONTROL | VARIABLE |
SOLENOID | REGULATOR |
PLUNGER
SOLENOID
JAM NUT
Figure 12.4 Install the Flame Solenoid
54 | Heat & Glo • |