Heat & Glo LifeStyle PIER-36TRLP-IPI C. Facing Material, Top View, 1/2 in, Fireplace, 2-3/4, 1 in

Models: PIER-36TR-IPI PIER-36TRLP-IPI ST-36TRLP-IPI ST-36TR-IPI

1 85
Download 85 pages 56.19 Kb
Page 60
Image 60
C. Facing Material

TOP VIEW

1/2 in.

Min.

FIREPLACE

2-3/4

OPENING

 

 

in. Min.

 

 

Unlimited

 

1 in.

 

 

Max.

 

 

 

 

 

Note: Clearance from opening to perpendicular wall.

Figure 13.16 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening)

C. Facing Material

Metal front faces may be covered with non-combustible materials only.

Facing and/or finishing materials must not interfere with air flow through louvers, operation of louvers or doors, or access for service.

Facing and/or finishing materials must never overhang into the glass opening.

Observe all clearances when applying combustible materials.

Seal joints between the finished wall and appliance top and sides using a 300 °F minimum sealant. Refer to Figure 13.17.

WARNING! Risk of Fire! DO NOT apply combustible materials beyond the minimum clearances. Comply with all minimum clearances to combustibles as specified in this manual. Overlapping materials could ignite and will interfere with proper operation of doors and louvers.

Finish wall material may be combustible - Top and Sides

 

0 in.

0 in.

0 in.

High Temperature Sealant (300° F/149° C min.)

Top and Side Seal Joint

Figure 13.17 Noncombustible Facing Diagram