Manuals
/
Heat & Glo LifeStyle
/
Household Appliance
/
Burner
Heat & Glo LifeStyle
ST-36TRLP-IPI, PIER-36TRLP-IPI 22 Pier Door Finishing, 33-5/8 in, 37-1/4 in
Models:
PIER-36TR-IPI
PIER-36TRLP-IPI
ST-36TRLP-IPI
ST-36TR-IPI
1
62
85
85
Download
85 pages
56.19 Kb
59
60
61
62
63
64
65
66
<
>
Troubleshooting
Install
FAQ
C. Service Parts
Vent Information and Diagrams
Ember Light Replacement
Warranty
Dimension
Maintenance
A. Wiring Requirements
Page 62
Image 62
FINISHING
MATERIAL
33-5/8
in.
37-1/4
in.
Figure 13.22 Pier Door Finishing
62
Heat & Glo •
ST-36TR-IPI,
PIER-36TR-IPI
•
2176-900
Rev. F • 8/11
Page 61
Page 63
Page 62
Image 62
Page 61
Page 63
Contents
Owner’s Manual
Models ST-36TR-IPI ST-36TRLP-IPI PIER-36TR-IPI PIER-36TRLP-IPI
What to do if you smell gas
Read this manual before installing or operating this appliance
A. Congratulations
Homeowner Reference Information
Please retain this owner’s manual for future reference
Installer Guide
Table of Contents
Safety Alert Key
7 Vent Information and Diagrams
= Contains updated information
14 Appliance Setup
15 Troubleshooting
13 Finishing
WARRANTY COVERAGE
B. Limited Lifetime Warranty
Hearth & Home Technologies Inc LIMITED LIFETIME WARRANTY
WARRANTY PERIOD
WARRANTY EXCLUSIONS
B. Limited Lifetime Warranty continued
WARRANTY CONDITIONS
This warranty is void if
A. Appliance Certification
D. High Altitude Installations
1 Listing and Code Approvals
B. Tempered Glass Specifications
Approved Carbon Monoxide Detectors
H. Requirements for the Commonwealth of Massachusetts
Installation of Carbon Monoxide Detectors
Signage
B. Your Fireplace
A. Gas Fireplace Safety
2 Operating Instructions User Guide
G. Remote Controls, Wall Controls and Wall Switches
Blower Installation
F. Fixed Glass Assembly
C. Blower Kit optional
TO TURN OFF GAS TO APPLIANCE
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS IPI
I. Lighting Instructions IPI
ISSUE
K. Frequently Asked Questions
J. After Fireplace is Lit
SOLUTIONS
Glass Cleaning
3 Maintenance and Service
A. Maintenance Tasks-Homeowner
Remote Control
Gasket Seal and Glass Assembly Inspection
Ember Light Replacement
B. Maintenance Tasks-Qualified Service Technician
Logs
Figure 3.4 IPI Pilot Flame Patterns
Burner Ignition and Operation
Frequency Annually
Installer Guide
Getting Started
A. Typical Appliance System
Figure 4.1 Typical System
D. Inspect Appliance and Components
B. Design and Installation Considerations
C. Tools and Supplies Needed
36 in
5 Framing and Clearances
A. Selecting Appliance Location
36 in
B. Constructing the Appliance Chase
C. Clearances
PIER-36TR-IPI
C B D
E I H G
Inches
PIER Combustible Mantel
D. Mantel and Wall Projections
See-Through Combustible Mantel
See-Through Non-Combustible Mantel
FIREPLACE
TOP VIEW
1/2 in
2-3/4
Roof Pitch
6 Termination Locations
A. Vent Termination Minimum Clearances
H Min. Ft
Local codes or regulations may require different clearances
X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED
Covered Alcove Applications
Vent system termination is NOT permitted in screened porches
To Install the Heat Shield
C. Install Support Brackets
B. Continue Adding Vent Components
B. Vent Table Key
7 Vent Information and Diagrams
A. Approved Pipe
C. Use of Elbows
to SLP series vent pipe, if desired
E. Vent Diagrams
Note The Multi-Sided series fireplaces can adapt
1. Top Vent - Horizontal Termination - continued
1. Top Vent - Horizontal Termination - continued
One Elbow
Two Elbows
V1 Minimum
continued
1. Top Vent - Horizontal Termination
Three Elbows
H2 V2
Exhaust restrictor Instructions
2. Top Vent - Vertical Termination No Elbow V1 = 60 ft. Max. 18.3 m
V1 = 3 ft. Min. 914 mm
BREAK HERE
H 1 Maximum
Two Elbows
Three Elbows
V 1 + V 2 Minimum
One 45 Elbow
3. Rear Vent - Horizontal Termination No Elbow
H1 = 16 in. 406 mm Maximum
Heat & Glo ST-36TR-IPI, PIER-36TR-IPI 2176-900 Rev. F 8/11
Three Elbows
3. Rear Vent - Horizontal Termination - continued
Two Elbows
V1 H1
V1 Minimum
4. Rear Vent - Vertical Termination One Elbow
Two Elbows
H1 Maximum
Three Elbows
4. Rear Vent - Vertical Termination - continued
Three Elbows
H1 Maximum
B. Wall Penetration Framing
8 Vent Clearances and Framing
A. Pipe Clearances to Combustibles
Between ceiling firestops Between wall shield firestops
C. Vertical Penetration Framing
Vaulted Ceiling Installation
D. Install Attic Insulation Shield
Flat Ceiling Installation
NOTICE Once the vent cap has been removed it CANNOT be reattached
9 Appliance Preparation
A. Top Vent
Proceed to Section 9. C
Figure 9.6 Remove the seal cap
B. Rear Vent
Figure 9.5 Cut the metal retaining band
NOTICE Once the vent cap has been removed it CANNOT be reattached
Sagging or loose insulation Insulation backing or plastic
C. Securing and Leveling the Appliance
WARNING! Risk of Fire! Prevent contact with
Framing and other combustible materials
Attach Vent to the Firebox Assembly
10 Installing Vent Pipe DVP and SLP Pipe
A. Assemble Vent Sections DVP Pipe Only
Assemble Pipe Sections DVP Pipe Only
Pilot hole
B. Assemble Vent Sections SLP Pipe Only
C. Assemble Slip Sections
Only outer pipes are sealed, sealing the inner flue is not required
D. Secure the Vent Sections
E. Disassemble Vent Sections
CUT HOLE 1/8 in. 3 mm GREATER IN SIZE THAN PATTERN OF SUPPORT
F. Install Decorative Ceiling Components SLP only
LEVEL CATHEDRAL CEILING SUPPORT BOX
BOX AS IT IS PROJECTED ONTO ROOF LINE
CAULK
G. Install Metal Roof Flashing
H. Assemble and Install Storm Collar
CAUTION! Risk of Cuts, Abrasions or Flying Debris
K. Heat Shield Requirements for Horizontal Termination
I. Install Vertical Termination Cap
J. Install Decorative Wall Components SLP only
Heat shields must overlap 1-1/2 in. 38 mm mini- mum
Failure to maintain overlap may cause overheating and fire
L. Install Horizontal Termination Cap DVP and SLP Pipe
1-1/2 38 mm minimum overlap of flue telescoping section is required
B. Gas Pressure
11 Gas Information
A. Fuel Conversion
C. Gas Connection
B. IntelliFire Ignition System Wiring
A. Wiring Requirements
D. Junction Box Installation
C. Electrical Service and Repair
Determine Location
E. WSK-MLT Multifunction Wall Switch
Precautions
Wiring the Wall Switch
Figure 12.2 Intellifire IPI Wiring Diagram
F. Install the Flame Solenoid
G. Connect the Temperature Sensor Switch for Fan optional
H. WSK-MLT Operating Instructions
I. Setting Flame Height/Manifold Pressure
J. Wall Switch Button Operation
Temperature Button
Up and Down Arrows
Set Temperature Button
Operation Under Battery Power
Auxiliary Button
To install the Splatter Guard
13 Finishing
A. Splatter Guard
Figure 13.8 Opening Lower Access Panel
To Close the Lower Access Panel
Figure 13.7 Prepare to Open Lower Access Panel
Figure 13.10 Splatter Guard with Lower Access Panel Open
Dimensions of Combustibles
B. Mantel and Wall Projections
Dimensions of Combustibles
Dimensions of Non-Combustibles
1/2 in
C. Facing Material
TOP VIEW
FIREPLACE
PIER-36TR-IPI
D. Finishing Material
ST-36TR-IPI
FINISH MATERIAL
33-5/8 in
Figure 13.22 Pier Door Finishing
Heat & Glo ST-36TR-IPI, PIER-36TR-IPI 2176-900 Rev. F 8/11
37-1/4 in
E. Elevated Hearth Systems
Note 3. Dimensions assume use of a 3/4 in. Hearth Pad
C. Clean the Appliance
14 Appliance Setup
A. Remove Fixed Glass Assembly
D. Accessories
Placing the Ember Material
PILOT ASSEMBLY
Log Set Assembly LOGS-MSR
F. Install the Log Assembly
ASSEMBLY
4 3/4 IN
3 2 5 4
SHARP NOTCH
SHARP NOTCH
FLAT AREA
3 2 54 1
3 4 6
Notch
I. Air Shutter Setting
G. Fixed Glass Assembly
H. Install Trim Kits and Surrounds
Removing Fixed Glass Assembly
Symptom
15 Troubleshooting
A. IntelliFire Ignition System
Possible Cause
Possible Cause
IntelliFire Ignition System - continued
Symptom
Corrective Action
Location
A. Appliance Dimension Diagram
16 Reference Materials
Inches
ELECTRICAL
ACCESS
GAS LINE ACCESS G LEFT VIEW
C D N
DVP-AS2
B. Vent Components Diagrams
Height 24 in./610 mm
Heat & Glo
DVP-TRAP2
B. Vent Components Diagrams continued
DVP-TRAP1
DVP-TRAPK1
787 mm
B. Vent Components Diagrams continued
31 in
13-1/4 in
98 mm
B. Vent Components Diagrams continued
3-7/8 in
10-1/2 in
Optional Wire Harness
DVP-HRC-SS
B. Vent Components Diagrams continued
DESCRIPTION
45 Elbow
B. Vent Components Diagrams continued
SLP45
SLP90 90 Elbow
SLP-DCF-BK
B. Vent Components Diagrams continued
ASSEMBLY
SLK-SNKD
ST-36TR-IPI
C. Service Parts
Log Set Assembly
at Depot
C. Service Parts
PIER-36TR-IPI
Stocked
Log Set Assembly
PIER-36TR, ST-36TR-IPI
#17 Valve Assembly
C. Service Parts
at Depot
Stocked
C. Service Parts List
ST-36TR-IPI, PIER-36TR-IPI
at Depot
Please contact your Heat & Glo dealer with any questions or concerns
D. Contact Information
DO NOT DISCARD THIS MANUAL