Heat & Glo LifeStyle ST-36TRLP-IPI Rear Vent - Horizontal Termination - continued, Two Elbows

Models: PIER-36TR-IPI PIER-36TRLP-IPI ST-36TRLP-IPI ST-36TR-IPI

1 85
Download 85 pages 56.19 Kb
Page 34
Image 34
3. Rear Vent - Horizontal Termination - (continued)

3. Rear Vent - Horizontal Termination - (continued)

Two Elbows

H1 Maximum

V1 Minimum

H2 Maximum

H1+ H2 Maximum

1 ft.

610 mm

6 in.

152 mm

1 ft.

305 mm

1 ft

305 mm

2 ft.

914 mm

1 ft.

305 mm

2 ft.

610 mm

3 ft.

914 mm

3 ft.

914 mm

2 ft.

610 mm

4 ft

1.2 m

6 ft.

1.8 m

3 ft.

914 mm

3 ft.

914 mm

7 ft.

2.1 m

9 ft.

2.7 m

3 ft.

914 mm

4 ft.

1.2 m

10 ft.

3 m

12 ft.

3.7 m

3 ft.

914 mm

5 ft.

1.5 m

12 ft.

3.7 m

15 ft.

4.6 m

3 ft.

914 mm

6 ft.

1.8 m

15 ft.

4.6 m

18 ft.

5.5 m

V1+ H1+ H2= 50 ft (15.2 m) Maximum H1= 3 ft (914 mm) Maximum

*H1+ H2= 18 ft (5.5 m) Maximum

H2

Figure 7.15

V1

H1

Three Elbows

 

H1 Maximum

V1 Minimum

H2+ H3

H1+ H2+ H3

Maximum

6 in.

152 mm

6 in.

152 mm

6 in.

152 mm

1 ft.

 

305 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 ft.

305 mm

1 ft.

305 mm

2 ft.

610 mm

3 ft.

 

914 mm

 

 

3 ft.

914 mm

2 ft.

610 mm

3 ft.

914 mm

6 ft.

 

1.8 m

 

 

3 ft.

914 mm

3 ft.

914 mm

6 ft.

1.8 m

9 ft.

 

2.7 m

 

 

3 ft.

914 mm

4 ft.

1.2 m

9 ft.

2.7 m

12 ft.

 

3.7 m

INSTALLED

V1+ H1+ H2+ H3= 40 ft (12.2 m) Maximum

H1= 3 ft (94 mm) Maximum

HORIZONTALLY

 

 

H1+ H2+ H3= 12 ft (3.7 m) Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H3H2

V1

H1

Figure 7.16

34

Heat & Glo • ST-36TR-IPI, PIER-36TR-IPI2176-900 Rev. F • 8/11

Page 34
Image 34
Heat & Glo LifeStyle ST-36TRLP-IPI Rear Vent - Horizontal Termination - continued, Two Elbows, Three Elbows, V1 H1, H 2+ H