Wiring the Wall Switch
•Install the provided control wire from the fireplace to the switch location. (Control wire for Heatilator products is supplied with the fireplace).
NOTICE: Do not to stress the wire around tight or sharp corners. Do not run the control wire adjacent to existing or future phone, data, cable, or electrical lines. The wire should not come into contact with any part of the fireplace exterior with the exception of where it exits the outer wrap.
•Feed the wire to the electrical junction box and through a provided or approved strain relief.
•Connect the wires to the terminals as shown in Figure 12.2. Do not
•Using the screws provided, mount the switch to the electrical junction box right side up.
•Install provided cover plate using the screws provided. Do not use a substitute cover even though it may fit. The provided one is specifically designed for the automatic (thermostat) function of the unit.
BLACK |
WHITE |
BROWN |
BATTERIES
* May be labeled as “W” or “Y”.
ORANGE | GREEN |
|
BLACK RED
YELLOW OR
WHITE
RED
REAR VIEW
IPI
VALVE
FLAME SOLENOID
GROUND
BLACK
Red (MALE/FEMALE)
1
IPI2
MODULE 3 4 5 6 7 8
Red (MALE/FEMALE)
3V DC
BROWN
BROWN
RED
BLACK
*
GREEN
*
FRONT VIEW
FLAME ON | RED |
| |
| RED |
| |
|
| ORANGE | |
FLAME HIGH/LOW | AC | ORANGE | |
ADAPTER WIRES |
| ||
PLUG | BLACK | ||
| |||
|
| ||
|
| BLACK | |
EMBER LIGHT | AUX | GROUND PIGTAIL | |
CONNECTION | |||
CONNECTOR BLOCK |
| GREEN | |
SEE DETAIL IN FIGURE 12.3 |
|
|
YELLOW (FEMALE/FEMALE)
YELLOW
FAN THERMOSTAT
BLACK
FAN
CONNECTION
TEMPERATURE SENSOR SWITCH
FAN CORD
BLACK
Figure 12.2 Intellifire (IPI) Wiring Diagram
Heat & Glo • | 53 |