Timer Settings

Model CF-941

3-6. OPERATION AND

Timer Settings

PROGRAMMING

To change a timer setpoint, press and hold the desired

(Continued)

 

timer button, then use the UP and DOWN buttons to

 

change the time. Releasing the timer button enters the

 

time into the controls. If “Loc” shows in the display

 

when the UP or DOWN button is pressed, the controls

 

must be unlocked before temperature can be changed.

 

(See Special Program Mode).

When programming the setpoint temperature or timers, pressing and holding the UP or DOWN buttons will speed up the displayed digits.

Special Program Mode

1.Turn the POWER switch off. Then press and hold both the UP and DOWN buttons and turn the POWER switch back on. Hold in on the UP and DOWN buttons until SP shows on the display, then release the UP and DOWN buttons. Display will now show “ºF” or “ºC”.

2.Press the UP or DOWN buttons to toggle from “ºC (Celsius), to “ºF” (Fahrenheit).

3.Press and release the SET button. The display will show “P=U” or “P=L”, which means program unlock(U) or lock(L). The UP and DOWN buttons toggle from U to L. The display must show “P=U” before the temperature or times can be changed.

4.Press and release the SET button 2 times and the display will show “H=n” or “H=y”, which means

Hours=no(n) or Hours=yes(y). “H=n” means the timers will time in minutes and seconds, and “H=y” the timers will time in hours and minutes.

5.Press and release the SET button 3 times and the display will show “CAL”. To calibrate the temperature, press and hold the TEMP button,

and use the UP and DOWN buttons to match the display to the actual temperature.