3-6. OPERATION AND

Model CF-941

3-6. OPERATION AND

Unit Operation

PROGRAMMING

 

Before operating the holding cabinet, read and understand this complete operation manual (supplied with each unit). The following steps are meant to be guidelines, not complete operating instructions.

1.Turn POWER switch to the ON position.

2.The display will show the setpoint temperature.

Press the TEMP button at any time to view actual temperature. The LED will light when the actual temperature is on the display.

3.When temperature LED illuminates, the unit setpoint temperature has been reached and product can be loaded into the pans. Load product into a pan inside the drawer and press appropriate timer button, either 1, 2, or 3.

4.At the end of the timing cycle, the display will flash “0:00” and the timer LED will flash.

If more than one timer is running at the same time, the timer with the least amount of time will be the one displayed and the LED will be flashing, indicating which timer is being displayed. Pressing and releasing the SET button will toggle through the different running times.

Temperature Setpoint Programming

Press and hold the TEMP button for 5 seconds, and the setpoint temperature will start flashing and the LED will turn off. Continue to hold in on the TEMP button, then use the UP and DOWN buttons to set the desired setpoint temperature. Releasing the TEMP button enters the setpoint into the controls. If “Loc” shows in the display when the UP or DOWN button is pressed, the controls must be unlocked before temperature can be changed. (See Special Program Mode).

3-4