Hill Phoenix 05DMA manual Use And Maintenance, Case Cleaning, Cleaning Procedures, Danger

Models: 05DMA

1 32
Download 32 pages 40.02 Kb
Page 24
Image 24
USE AND MAINTENANCE

USE AND MAINTENANCE

CASE CLEANING

Case is designed to facilitate cleaning. There is a wide radius formed on the front and back of the inside bottom that helps accelerate liquid flow and eliminates difficult-to- clean sharp corners. All surfaces pitch to a deep-drawn drain trough that angles toward the front and center of case where the waste outlet is located for easy access.

The coil is covered to keep food fluids from entering, but the cover lifts up easily when coil cleaning is desired. The single piece fan plenum lifts up for cleaning, exposing a major portion of the inside bottom of the tank. Make cer- tain fan plenum is properly closed after cleaning to avoid air leaks. Front return air grills snap out for cleaning; no fasteners are used.

In order to keep the unit running at peak design efficiency the air intake grill and the condenser coil should be cleaned at least once a month.

SINGLE PIECE FAN

PLENUM SWINGS

UP FOR EASY

CLEANING

PLENUM

COIL

POSITIVE DRAIN OFF

SINGLE PIECE FAN PLENUM LIFT UP

LOOSEN

HONEYCOMB

SCREW

 

 

SLIDE REAR HONEYCOMB

 

RETAINER BACK AND

 

REMOVE HONEYCOMB

CLEAN HONEYCOMB

CLEANING PROCEDURES

A periodic cleaning schedule should be established to maintain proper sanitation, insure maximum operating efficiency, and avoid the corrosive action of food fluids on metal parts that are left on for long periods of time. We recommend cleaning once a week.

To avoid shock hazard, be sure all electrical power is turned off before cleaning. In some installations, more than one disconnect switch may have to be turned off to completely de-energize the case.

Check waste outlet to insure it is not clogged before starting the cleaning process and avoid introducing water faster than the case drain can carry it away.

Avoid spraying cleaning solutions directly on fans or electrical connections.

Provide a temporary separator between those cases which are being cleaned and those which are not.

Allow cases to be turned off long enough to clean any frost or ice from coil and flue areas.

Remove and clean discharge honeycomb. You may need to use spray detergent and a soft, long bristle brush.

Use mild detergent and warm water. When necessary, water and baking soda solution will help remove case odors. Avoid abrasive scouring powders or pads.

Remove front panels and clean underneath the case with a broom and a long handled mop. Instructions for removing the front panels can be found on page 6 of this manual.

Use warm water and a disinfecting cleaning solution when cleaning underneath the cases.

DANGER

Electrical Shock Hazard Always disconnect power to case

when servicing or cleaning.

20