USE AND MAINTENANCE

USE AND MAINTENANCE

CASE CLEANING

Case is designed to facilitate cleaning. There is no mechanical or electrical controls in the product area to hamper routine cleaning. All surfaces pitch to a deep- drawn drain trough that angles toward the front and center of case where the 2” waste outlet is located for easy access.

The coil and fan plenum are located outside the product area to keep food fluids from entering, diminish downtime, and reduce shrink. If cleaning is required, make certain fan plenum is properly closed after cleaning to avoid air leaks.

LIFT UP TOP

HATCH TO EASILY

ACCESS COIL

AND PLENUM

TOP HATCH

POSITIVE DRAIN OFF

COIL CLEANING

HONEYCOMB

REAR

HONEYCOMB

RETAINER

SCREW

LOOSEN SCREWS IN

REAR HONEYCOMB

RETAINER AND

TWIST HONEYCOMB

OUT

CLEAN HONEYCOMB

CLEANING PROCEDURES

A periodic cleaning schedule should be established to maintain proper sanitation, insure maximum operating efficiency, and avoid the corrosive action of food fluids on metal parts that are left on for long periods of time. We recommend cleaning once a week.

To avoid shock hazard, be sure all electrical power is turned off before cleaning. In some installations, more than one disconnect switch may have to be turned off to completely de-energize the case.

Check waste outlet to insure it is not clogged before starting the cleaning process and avoid introducing water faster than the case drain can carry it away.

Avoid spraying cleaning solutions directly on fans or electrical connections.

Provide a temporary separator between those cases which are being cleaned and those which are not.

Allow cases to be turned off long enough to clean any frost or ice from coil and flue areas.

Remove and clean discharge honeycomb. You may need to use spray detergent and a soft, long bristle brush.

Use mild detergent and warm water. When necessary, water and baking soda solution will help remove case odors. Avoid abrasive scouring powders or pads.

Remove front panels and clean underneath the case with a broom and a long handled mop. Instructions for removing the front panels can be found on page 6 of this manual.

Use warm water and a disinfecting cleaning solution when cleaning underneath the cases.

When cleaning antifog doors please refer to Appendix A, on page 26, for more details.