Hill Phoenix ORBH, ONRBH manual High Glass Door Reach-in Beverage Merchandiser

Models: ONRB ORB ONRBH ORBH

1 44
Download 44 pages 35.04 Kb
Page 31
Image 31

High Glass Door Reach-in Beverage Merchandiser

ORBH - 2, 3, 4, 5, 6-door, 8’ & 12’

Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Efficiency

Anti-Condensate

 

Defrost Heaters

 

 

 

 

 

 

 

Standard Fans

 

Fans

Heaters

 

 

 

 

 

 

Fans per

 

 

120 Volts

 

 

120 Volts

120 Volts

208 Volts

240 Volts

 

 

Model

 

Case

 

Amps

 

Watts

 

Amps

Watts

Amps

Watts

Amps

Watts

Amps

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORBH

2-door

2

 

 

1.00

 

60

 

0.31

18.4

1.06

127

4.39

914

5.06

1215

 

 

 

3-door

3

 

 

1.50

 

90

 

0.46

27.6

1.55

186

4.96

1032

5.71

1370

 

 

 

4-door

4

 

 

2.00

 

120

 

0.61

36.8

2.07

248

6.51

1355

7.55

1813

 

 

 

5-door

5

 

 

2.50

 

150

 

0.77

46.0

2.54

305

7.96

1655

9.17

2201

 

 

 

6-door

6

 

 

3.00

 

180

 

0.92

55.2

3.07

368

9.40

1955

10.79

2589

 

 

 

8’

3

 

 

1.50

 

90

 

0.70

42

1.61

193

3.85

800

4.44

1065

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12’

4

 

 

2.00

 

120

 

0.93

56

2.23

268

5.78

1200

6.67

1600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lighting Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical per

 

Maximum

 

 

 

 

 

 

 

 

 

 

 

 

 

Light Row

 

Lighting

 

 

 

 

 

 

 

 

 

 

 

 

 

120 Volts

 

120 Volts

 

 

 

 

 

 

 

 

 

 

 

Model

 

Amps

Watts

Amps

 

Watts

 

 

 

 

 

 

 

 

 

 

 

ORBH

2-door

NA1

NA

 

1.50

 

180

 

 

 

 

 

 

 

 

 

 

 

 

 

3-door

NA

NA

 

1.90

 

228

 

 

 

 

 

 

 

 

 

 

 

 

 

4-door

NA

NA

 

2.40

 

288

 

 

 

 

 

 

 

 

 

 

 

 

 

5-door

NA

NA

 

2.90

 

348

 

 

 

 

 

 

 

 

 

 

 

 

 

6-door

NA

NA

 

3.40

 

408

 

 

 

 

 

 

 

 

 

 

 

 

 

8’

NA

NA

 

1.90

 

228

 

 

 

 

 

 

 

 

 

 

 

 

 

12’

NA

NA

 

2.40

 

288

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1Not applicable.

Guidelines & Control Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil

Evaporator

Superheat Set

Discharge Air

Return Air

Discharge Air Velocity5

 

 

Model2

BTUH/door3

Type

(°F)

Point @ Bulb (oF)

(°F)

(°F)

(FPM)

 

 

ORBH-2, 3, 4, 5

& 6dr - Deli/Dairy

8304

Enh.

32

6-8

36

38

280

 

 

ORBH-2, 3, 4, 5

& 6dr - Beverage

8004

Enh.

34

6-8

38

40

280

 

 

ORBH-8’ & 12’ Deli/Dairy

9304

Enh.

32

6-8

36

38

280

 

 

ORBH-8’ & 12’- Beverage

9004

Enh.

34

6-8

38

40

280

 

 

 

 

 

 

 

 

 

 

 

 

2ORBH-8’ has 3 doors, ORBH-12’ has 4 doors.

3BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04.

4High efficiency fans reduce refrigeration load by 96 BTUHs/fan.

5Average discharge air velocity at peak of defrost.

Defrost Controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric Defrost

Timed Off Defrost

Hot Gas Defrost

Reverse Air Defrost

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Defrosts

Run-Off

Fail-safe

Termination

Fail-safe

Termination

Fail-safe

Termination

Fail-safe

Termination

 

 

Per Day

Time (min)

(min)

Temp. (°F)

(min)

Temp. (°F)

(min)

Temp. (°F)

(min)

Temp. (°F)

 

 

ORBH

46

6 - 8

30

47

30

40

24

47

- - -7

- - -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6If timed off defrost is utilized. If electric or hot gas defrost is utilized case only requires 1 defrots per day.

7NOTE: - - - not an option on this case model.

Medium Temperature Defrost Schedule

No. Per Day

Hours

112 midnight

212 am - 12 pm

36 am - 2 pm - 10 pm

4

12 - 6 am - 12 - 6 pm

All measurements are taken per ARI 1200 - 2002 specifications.