CASE OPERATION

Glass Door Reach-in Beverage Merchandiser

ORB - 2, 3, 4, 5 & 6-door

Electrical Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Efficiency

Anti-Condensate

 

Defrost Heaters

 

 

 

 

 

Fans

Standard Fans

Fans

Heaters

 

 

 

 

 

 

120 Volts

120 Volts

120 Volts

208 Volts

240 Volts

 

 

 

 

per

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

Case

Amps

Watts

Amps

Watts

Amps

Watts

Amps

Watts

Amps

Watts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ORB

2-door

2

1.00

60

0.31

18.4

1.01

121

4.39

914

5.06

1215

 

 

 

3-door

3

1.50

90

0.46

27.6

1.49

179

4.96

1032

5.71

1370

 

 

 

4-door

4

2.00

120

0.61

36.8

1.96

235

6.51

1355

7.55

1813

 

 

 

5-door

5

2.50

150

0.77

46.0

2.40

288

7.96

1655

9.17

2201

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-door

6

3.00

180

0.92

55.2

2.92

350

9.40

1955

10.79

2589

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lighting Data

 

 

 

 

 

 

 

 

 

 

 

Typical per

Maximum

 

 

 

 

Light Row

Lighting

 

 

 

 

120 Volts

120 Volts

 

 

Model

Amps

Watts

Amps

Watts

 

 

ORB

2-door

NA1

NA

1.50

180

 

 

 

3-door

NA

NA

1.90

228

 

 

 

4-door

NA

NA

2.40

288

 

 

 

5-door

NA

NA

2.90

348

 

 

 

6-door

NA

NA

3.40

408

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 Not applicable.

Guidelines & Control Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

Coil

Evaporator

Superheat Set

Discharge Air

Return Air

Discharge Air Velocity4

 

 

Model

BTUH/door2

Type

(°F)

Point @ Bulb (oF)

(°F)

(°F)

(FPM)

 

 

ORB - Deli/Dairy

8303

Enh.

32

6-8

36

38

380

 

 

ORB - Beverage

8003

Enh.

34

6-8

38

40

380

 

 

 

 

 

 

 

 

 

 

 

2BTUHs/door listed are for parallel operation. Conventional ratings may be approximated by multiplying listed rating by 1.04.

3High efficiency fans reduce refrigeration load by 96 BTUHs/fan.

4Average discharge air velocity at peak of defrost.

Defrost Controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electric Defrost

Timed Off Defrost

Hot Gas Defrost

Reverse Air Defrost

 

 

Model

Defrosts

Run-Off

Fail-safe

Termination

Fail-safe

Termination

Fail-safe

Termination

Fail-safe

Termination

 

 

Per Day

Time (min)

(min)

Temp. (°F)

(min)

Temp. (°F)

(min)

Temp. (°F)

(min)

Temp. (°F)

 

 

ORB

45

6 - 8

30

47

30

40

24

47

- - -6

- - -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5If timed off defrost is utilized. If electric or hot gas defrost is utilized case only requires 1 defrost per day.

6NOTE: - - - not an option on this case model.

Medium Temperature Defrost Schedule

No. Per Day

Hours

112 midnight

212 am - 12 pm

36 am - 2 pm - 10 pm

412 - 6 am - 12 - 6 pm

All measurements are taken per ARI 1200 - 2002 specifications.

COMPONENT

26

Page 30
Image 30
Hill Phoenix ORBH, ONRBH manual Case Operation