Hill Phoenix ONRBH, ORBH manual Model Orbh, Coil

Models: ONRB ORB ONRBH ORBH

1 44
Download 44 pages 35.04 Kb
Page 9
Image 9

41 7/16 in [105.2 cm]

 

 

 

Amp plate &

 

 

 

Serial Plate

 

 

 

location

 

 

68 in

 

 

 

[172.7 cm]

 

 

 

(Frame Height)

 

85 1/16 in

63 in

 

 

[160.1 cm]

 

 

[216.0 cm]

66 3/8 in

 

 

 

 

 

[168.6 cm]

 

87 1/16 in

 

(Door Height)

 

 

 

 

[221.1 cm]

 

 

 

 

 

 

1/2 BUMPER OPTION

 

30 7/8 in [78.4 cm]

 

 

 

COIL

16 1/16 in

7 1/2 in

 

PLENUM

[19.1 cm]

 

 

[40.9 cm]

 

5 1/8 in

6 13/16 in [17.2 cm]*

8 1/2 in

 

[21.6 cm]

 

 

 

[13.1 cm]

31 9/16 in [80.2 cm]

 

 

 

 

 

 

 

39 1/4 in [99.7 cm]

 

 

 

42 11/16 in [108.4 cm]

 

 

 

 

 

PIPING-TO-TOP

 

 

 

(OPTIONAL)

MODEL

ORBH

 

 

WIRING-TO-TOP

 

 

REAR REFRIGERATION

 

 

 

 

(13 15/16" off of floor)

8 in [20.3 cm]

 

(OPTIONAL)

12 3/4 in [32.4 cm]

 

3 3/8 in [8.6 cm]

 

 

 

 

 

10 in

 

 

 

 

 

[25.4 cm]

 

 

 

4 in [10.2 cm]

28 5/8 in

 

 

 

35 1/8 in

 

 

 

 

[72.7 cm]

 

 

 

[89.2 cm]

 

31 9/16 in

 

 

 

 

 

 

**

 

33 9/16 in

[80.2 cm]

 

 

 

 

 

 

 

 

 

 

 

 

[85.3 cm]

34 11/16 in

 

 

 

 

 

[88.1 cm]

 

ELECTRICAL

 

 

39 1/4 in

 

 

 

 

 

42 11/16 in

 

 

 

 

[99.7 cm]

 

 

 

 

 

[108.4 cm]

 

 

 

 

 

 

 

 

 

 

REFRIGERATION

JUNCTION BOX

 

 

 

 

1 1/2 in

(STANDARD)

 

 

 

 

[3.8 cm]

 

 

C

 

 

{END}

16 1/16 in [40.8 cm]

 

 

 

 

 

L

1 1/2" PVC DRAIN

8 11/16 in [22.1 cm]

 

 

18 9/16 in [47.1 cm]

 

CONNECTION

 

 

 

FRONT OF CASE

 

 

 

 

60 in [152.4 cm] {2 Door}

 

 

 

 

90 in [228.6 cm] {3 Door}

 

 

 

 

120 in [304.8 cm] {4 Door}

 

 

 

 

150 in [381.0 cm] {5 Door}

 

 

 

NOTES:

180 in [457.2 cm] {6 Door}

 

 

 

96 in [243.8 cm] {8' case}

 

 

 

 

 

 

 

 

144 in [365.8 cm] {12' case}

 

 

 

* STUB-UP AREA

 

 

 

 

** RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS

zENDS ADD APPROXIMATELY 1 INCH TO CASE HEIGHT

zWIRING-TO-THE-TOP- ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT

zA 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND A WALL

zSUCTION LINE (ALL LENGTHS) 1/2"

zLIQUID LINE (ALL LENGTHS) - 3/8", LIQUID LINE w/ HOT GAS DEFROST (ALL LENGTHS) - 1/2"

zAVAILABLE SHELF SIZES: WIRE SHELVES 16", 18", 20", 22" & 23 1/2"

SOLID SHELVES 18", 20", 22", 24" & 27"

(TOP SHELF MUST BE 24" OR SHORTER WHEN USING 27" SHELVES. RECOMMENDED CONFIGURATION IS 1 - 24" SHELF AND 4 - 27" SHELVES BELOW TOP SHELF)

5

Page 9
Image 9
Hill Phoenix ONRBH, ORBH manual Model Orbh, Coil