LCD TV Service Manual

equipment and the high voltage power supply block, it can result in electric shock or activation of the leakage-detection circuit breaker.

When installing the LCD module in, and removing it from the packing carton, be sure to have at least two persons perform the work.

When the surface of the panel comes into contact with the cushioning materials, be sure to confirm that there is no foreign matter on top of the cushioning materials before the surface of the panel comes into contact with the cushioning materials. Failure to observe this precaution may result in, the surface of the panel being scratched by foreign matter.

When handling the circuit board, be sure to remove static electricity from your body before handling the circuit board.

Be sure to handle the circuit board by holding the large parts as the heat sink or transformer. Failure to observe this precaution may result in the occurrence of an abnormality in the soldered areas.

Do not stack the circuit boards. Failure to observe this precaution may result in problems resulting from scratches on the parts, the deformation of parts, and short-circuits due to residual electric charge.

Routing of the wires and fixing them in position must be done in accordance with the original routing and fixing configuration when servicing is completed. All the wires are routed far away from the areas that become hot (such as the heat sink). These wires are fixed in position with the wire clamps so that the wires do not move, thereby ensuring

Hisense Confidential

- 8 -

Page 8
Image 8
Hisense LCD47P69P, LCD42P69P service manual Hisense Confidential