Hitachi 231580 manual Pressure Control

Models: 231580

1 34
Download 34 pages 50.54 Kb
Page 26
Image 26

Pressure Control

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, whenever you are instructed to relieve pressure, follow the Pressure Relief

Procedure on page 9.

NOTE: See Fig. 25 for this procedure.

7.Loosely install the screws (63) and then torque them to 21 in±lb (2.4 N.m).

8.Install the front cover (13). Connect the harness

(A) to the motor start board (47).

9.Install the junction box. Be sure no leads are pinched against the motor or by the motor start board.

NOTE: The pressure control (64) cannot be repaired or adjusted. If it has malfunctioned, replace it.

1.

Remove the front cover (13). Remove the screws

 

(56). Lower the junction box (59).

2.

Disconnect the harness connector (A) from the

 

motor start board (47).

3.

Remove the screws (63). Pull forward on the

 

pressure adjusting knob and tip the pressure

 

control (64) forward and up to detach it from the

 

drive housing (11).

4.

Guide the harness (A) through the motor and drive

 

housing and remove the pressure control.

5.

Guide the harness of the new pressure control

 

through the drive housing and motor passages.

64

63 1

11

A

13

6. Install the new pressure control. Tip the pressure

control down and back into the drive housing (11).

Do not pinch or damage the harness (A).

59

 

Torque to

56

1

21 in±lb (2.4 N.m)

 

 

 

Fig. 25

02816A

 

￿6 ￿￿87￿￿

Page 26
Image 26
Hitachi 231580 manual Pressure Control