Pressure Transducer Seal

Installation

1.Lightly coat cleaned packing recess in manifold with a light grease or oil.

2.Heat seal (69) in hot water for several minutes.

CAUTION

Excess pressure from the probes or fingernails will damage the packing and cause subsequent leakage.

3.Use a blunt wooden or plastic probe and install seal (69) into recess in manifold (229). Be careful not to cause kinks or bends in packing during installation.

4.Lightly grease or oil transducer (67) and install pump (18). See page 11.

69

229

Fig. 16

9666A

309067 17

Page 17
Image 17
Hitachi 309067 dimensions 9666A