Grounding

Grounding

WARNING

Read warnings, page 5, and follow instructions below.

1.Connect 12 gauge ground wire (provided by installer) from pneumatic control box (3) ground screw (312, page 22) to metering valve manifold (6). Refer to FIG. 3.

2.Connect ground wire from each pump (2) to meter- ing valve manifold (6).

3.Connect ground wire assembly (902) to fluid mani- fold (6). Connect clamp end to a true earth ground before starting unit.

Air Controls

Do not use air supply hose smaller than 3/4” (19

mm)ID. Smaller hose could restrict air flow and cause alternator, solenoids, or Mac valves to mal- function. Check air supply gauge at pump changeover; air pressure should not drop.

Assemble

Standard Setup

FIG. 1 and FIG. 3

1.Mount pneumatic control assembly (3) to mounting plate (10). FIG. 1.

2.Connect an air line (A and B) between each pneu- matic valve (501) and pump air motor inlet. FIG. 3.

Air Controls 36” (914 mm) hoses provided. Installer may pro- vide different lengths.

3.Connect air supply from air manifold’s 5 micron air filter (518) to control box air inlet (not shown).

Standard Setup The alternator requires 12-15 scfm of air to func- tion correctly.

Do not use 3/8” (9.5 mm) ID air supply tubing longer than 24” (610 mm) from air filter to control box air inlet.

Do not restrict control box exhaust air.

Increased back pressure can cause a drop in alternator power output, resulting in delayed valve action and processor shutdown and reboot.

4.Connect tubing (C and D) from solenoids to each pneumatic valve (501).

5.Mount air supply filter (901) to cart/stand and con- nect air supply (E) to air manifold (5) air inlet.