Pumps and Sensors
• If using feed pumps, do not allow feed pressure to exceed 25% of spray pressure.
•For accurate ratios, pump lowers must be same size.
•If installing 234024 or 234025, the pump size has not been set in the software. To set pump A and B size and A and B sensor calibration factors, you need Xtreme Mix Data Download software, part no. 246322 for proportioners located in a
Calibration values are on pump A and B sen- sors.
Pump Size Values
Pump | Size Value |
| (cc/cycle) |
|
|
45:1 | 250 |
|
|
56:1 | 220 |
|
|
68:1 | 180 |
|
|
80:1 | 145 |
|
|
1. | Secure magnet holders (903) to the pump (2) motor |
| displacement rods with screws (905). FIG. 1. |
2. | Install a short magnet strip then a long one (904) on |
| each magnet holder (903). Secure with tape sup- |
| plied. |
Assemble
Control Box
1.Mount control box (3) to mounting plate (10). FIG. 1.
a.Slide gasket (307) over back of pneumatic con- trol box (3), against lip. Insert box through mounting plate (10).
b.Secure box (3) to plate (10) with
Mount box (3) vertically for optimum alternator and component life.
2.Secure mounting plate (10) to cart/stand. Install fas- teners (provided by installer) through six 0.3” (7.62 mm) mounting plate holes.
3.Connect conduit (721) from two sensors (7) to pneu- matic control box (3).
Conduit must be used. Approximately 62” (1575
mm)of cable and conduit provided; do not lengthen.
4.Wire two sensors (7) to control box
5.Connect
10 9 8 7 6 5 4 3
3. Secure pumps (2) on mounting brackets with two |
3/8 x |
nuts (915). |
3
F
4. Secure sensors (7) on pumps and pump mounting |
brackets with two screws (913), lockwashers (914), |
and nuts (915). |
J2 J1
3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
- +
FIG. 2 Control Box
309521J | 9 |