User Interface
FIG. 4 and FIG. 5
1.Connect display board (410) communication cable (416) to J1 on main circuit board (301).
2.Connect data cable (406 -
WARNING
The user interface must be grounded. Read warnings, page 5.
3.Connect ground wire (315) to ground stud on back of cover with nut (311).
4.Secure cover (4) to mounting plate (10) with lock- washers (911) and nuts (910). FIG. 1.
410 | 4 |
311
416 | 406 |
FIG. 4: Cover - back view
Assemble
10 9 8 7 6 5 4 3
301
3
J2 J1
315 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 |
- +
FIG. 5 Control Box
Fluid Manifold
CAUTION
Do not assemble static mixer directly to fluid manifold. Install static mixer after first 50 ft. (15 m) of hose to ensure material is completely mixed. Spraying unmixed material could necessitate rework of part sprayed. See Setup in Xtreme Mix Operation manual.
Install Sampling Valves 244683
Install sampling valves (918) into the metering valves (601). Install barb fitting (919) and tubing (920) into each sampling valve. FIG. 7.
12 | 309521J |