Hitachi InstantSplit

Hitachi Data Systems

storage ports, multiple cache nodes, and multiple disk Array Control Processors (ACPs). Each path runs at 100MB/s, permitting the Lightning 9900to scale up to a total bandwidth of 6.4 GB/s. This is six-to-eight times the internal bandwidth of shared bus based storage systems. For redundancy and performance, Hi-Starconsists of four cache switches that are cross-connected to four cache modules and two control memory banks. These control memory banks contain addressing and control information and are also cross-connected to front-end storage ports and back-end disk array ports.

Hitachi InstantSplit

Hitachi InstantSplit is an enhancement to ShadowImagethat provides multiple copies of data against which new applications can be tested or data mining queries can be run even before (newly created) ShadowImagepairs have been fully synchronized. With InstantSplitand the Lightning 9900bottleneck-free performance, applications can be deployed faster, resulting in the faster delivery of products to market and better-targeted sales campaigns. See also ShadowImage.

Hitachi LUN Manager

Hitachi LUN Manager is a software utility in the Resource Manager 9000suite that allows for complete systems management of LUNs. See also LUN and Resource Manager9000.

Hitachi Multiplatform Backup/Restore

Hitachi Multiplatform Backup/Restore is a channel-based backup/restore of Open Systems volumes using standard mainframe utilities, which leverage current investment in hardware, software, skills, and procedures. Hitachi Multiplatform Backup/Restore provides high-performance, high bandwidth capabilities. One copy of software resides on each controller.

Hitachi RapidXchange

Hitachi RapidXchangeprovides for the file conversion and exchange of data between S/390® and open systems hosts. Hitachi Multiplatform Data Exchange provides file access library software for open systems hosts and runs on the following host servers: HP/UX®, AIX, Sun Solaris®, Compaq Tru64, UNIX®, Sequent DYNIX/ptx®, SGI IRIX®, NCR UNIX® SVR4, Windows NT®, and Windows 2000®.

Hitachi Multiplatform Resource Sharing

Hitachi Multiplatform Resource Sharing is built right into the Lightning 9900. With Hitachi Multiplatform Resource Sharing, Lightning 9900users can share resources between UNIX®- or Windows NT®/2000-based servers and S/390® mainframe platforms. Sharing resources across heterogeneous platforms lowers total cost of ownership, provides a centralized point for data management, and simplifies the management of heterogeneous systems..

60

Page 69
Image 69
Hitachi 9900 Series Hitachi Data Systems, Hitachi InstantSplit, Hitachi LUN Manager, Hitachi Multiplatform Backup/Restore