Hitachi KH-182B Care for main body, How to preserve, Specifications, Disposal of the product

Models: KH-182B

1 32
Download 32 pages 40.01 Kb
Page 16
Image 16

Care for main body

Wipe off the toner/moisturizing product on the head and the body with a tissue. When dirt is difficult to remove, wipe it off with a cloth after saturating it with water and wring it thoroughly.

Do not clean the main body with water. Or do not dip in water, and do not pour water. (Cause of failure)

Make sure to turn OFF the switch. (Improperly turning on the switch may give a tingling sensation or result in malfunction or short-circuit.)

CAUTION Do not use alcohol, benzine, or thinner. (Cause of deformation or discoloration)

How to preserve

Store the device on the included stand in a place free from excessive humidity or dirt. The stand can store the rings in it as well as put the body on it. (Fig. 12)

Do not leave in a water splashing area or an area with significant humidity, such as a bath. (Cause of short-circuits or failure)

CAUTION Do not leave in an area subject to direct sunlight (inside of a vehicle in summer, etc.) or near heaters. (Cause of deformation or discoloration)

Specifications

Power

Power adaptor

100 - 240V AC, common to 50-60Hz

(KH-182B)

supply

Main body

Batteries [Nickel-hydrogen battery (1.2V DC, 500mAh×2)]

 

 

 

Charging time

5 hours as standard

 

 

Rated time

Around 15 minutes at the maximum

 

 

(basic mode:approximate 10 minutes)

 

 

Accessories

Rings (two), stand

 

 

 

Disposal of the product

Do not disassemble except when disposing of the product.

This product includes recyclable parts.

For disposal of the parts, observe your local laws and regulations etc.

How to remove the nickel-hydrogen batteries

1.Keep pressing the power switch continuously while it is "ON" for about 10 seconds or more to make the device vibrate and leave it until the vibration stops.

2.Remove the two screws on the reverse side of the main body. (Fig. 13) Screws

3.Insert a flat-blade screwdriver or the like in the gap between the main body cases (front)

and (rear), and remove the main body case (rear). (Fig. 14)

Flat-blade screwdriver

Main body case (rear)

4.Cut the lead wires connected to the terminals of the nickel-hydrogen batteries near the terminals, and take out the batteries from the battery holder. (Fig. 15)

Main body case (front) Lead wires Nickel-hydrogen batteries Battery holder

Do not allow the (+) and (-) terminals of the removed nickel-hydrogen batteries to make contact. (Cause of a short circuit or burns)

-12-