B Group : Fine Tuning Functions
Restart after
Instantaneous
Power Failure
Electronic
Thermal
Software
Lock
Others
Selection of automatic restart mode
Allowable instantaneous power failure time
Time delay enforced before motor restart
Instantaneous power failure and under-voltage trip enable
Number of restarts after instantaneous power failure and under-voltage trip
Phase loss detection enable
Restart frequency setting
Electronic thermal characteristics
Electronic thermal characteristics for second motor
Free-setting electronic thermal frequency (1)
Free-setting electronic thermal current (1)
Free-setting electronic thermal frequency (2)
Free-setting electronic thermal current (2)
Free-setting electronic thermal frequency (3)
Free-setting electronic thermal current (3)
Deceleration rate at overload restriction
Deceleration rate at overload restriction (2)
RUN/ power-on warning time
Reduced voltage soft start selection
Function code display restriction
AM terminal analog meter adjustment
FM terminal analog meter adjustment
Start frequency adjustment
Carrier frequency setting
Country code for initialization
Frequency scaling conversion factor
STOP key enable
Resume on free-run stop cancellation mode
Dynamic braking usage ratio
Stop mode selection
Cooling fan control
Dynamic braking control
Dynamic braking activation level
Thermistor for thermal protection control
Thermistor for thermal protection level setting
Free-setting V/f frequency (1)
Free-setting V/f voltage (1)
Free-setting V/f frequency (2)
Free-setting V/f voltage (2)
Free-setting V/f frequency (3)
Free-setting V/f voltage (3)
Free-setting V/f frequency (4)
Free-setting V/f voltage (4)
Free-setting V/f frequency (5)
Free-setting V/f voltage (5)
Free-setting V/f frequency (6)
Free-setting V/f voltage (6)
Free-setting V/f frequency (7)
Free-setting V/f voltage (7)
0.3
-
25.0sec.
0.3
-
100.0sec.
00(Disable) / 01(Enable) / 02(Disable during stop and ramp to stop)
00(16 times) / 01(Always restart)
00(Disable) / 01(Enable)
0.00
-
99.99/100.0
-
400.0Hz
00(Reduced torque) / 01(Constant torque) / 02(V/f free-setting)
00(Reduced torque) / 01(Constant torque) / 02(V/f free-setting)
0.
-
400.Hz
0.0
-
1000.A
0.
-
400.Hz
0.0
-
1000.A
0.
-
400.Hz
0.0
-
1000.A
0.10
-
30.00
0.9999./10006553(10,00065,5300)hr (Output to intelligent terminal)
00(Short)
-
06(Long)
00(All) / 01(Utilized functions) / 02(User-selected functions only)
0
-
255
0
-
255
0.10
-
9.99Hz
0.5
-
12.0kHz (To be derated) {0.5
-
8kHz}(*1)
00(Japanese version) / 01(European version) / 02(North American version)
0.1
-
99.9
00(Enable) / 01(Disable)
00(Restart at 0Hz) / 01(Resume operation after frequency matching)
0.0
-
100.0%
00(Deceleration and stop) / 01(Free-run stop)
00(Fan is always ON) / 01(Fan is ON during RUN including 5min. afetr power-on and stop)
00(Disable) / 01(Enable during run) / 02(Enable during stop)
330-380/660-760V
00(Disable) / 01(PTC enable) / 02(NTC enable)
0.0
-
9999
0.
-
Free-setting V/f frequency (2)
0.0
-
800.0V
0.
-
Free-setting V/f frequency (3)
0.0
-
800.0V
0.
-
Free-setting V/f frequency (4)
0.0
-
800.0V
0.
-
Free-setting V/f frequency (5)
0.0
-
800.0V
0.
-
Free-setting V/f frequency (6)
0.0
-
800.0V
0.
-
Free-setting V/f frequency (7)
0.0
-
800.0V
0.
-
400.Hz
0.0
-
800.0V
00
1.0
1.0
00
00
01
0.00
01
01
0.
0.0
0.
0.0
0.
0.0
1.00
1.00
0.
06
00
180
60
0.50
3.0
01
1.0
00
00
0.0
00
00
00
360/720
00
3000
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Overload
Restriction
Free-setting
V/f pattern
00(Alarm output after trip, automatic restart disable) / 01(Restart at 0Hz) / 02(Re-
sume operation after frequency matching) / 03(Resume previous frequency after
frequency matching, then decelerate to stop and display trip information)
0.50*rated current
-
1.50*rated current
Overload restriction setting (2)
0.50*rated current-1.50*rated current
00(All parameters except b031 are locked when SFT from terminal is
on) / 01(All parameters except b031 and output frequency F001 are
locked when SFT from terminal is on) / 02(All parameters except
b031 are locked) / 03(All parameters except b031 and output fre-
quency F001 are locked) / 10(Run-time data edit mode)
Software lock mode selection

b031

b012

b212

Level of electronic thermal setting
Level of electronic thermal setting for second motor
0.20*rated current-1.20*rated current
0.20*rated current-1.20*rated current
Rated
current
Rated
current
00(Disable) / 01(Enable during accel./constant speed) /
02(Enable during constant speed) 01
Rated
current*
1.20
Rated
current*
1.20

b021

Overload restriction operation mode
Overload restriction setting

b022

0.10
-
30.00
00(Disable) / 01(Enable during accel./ constant speed) /
02(Enable at constant speed)

b024

b025

01
01
Overload restriction operation mode (2)
b035 Rotational direction restriction
00(Enable for both directions) / 01(Enable for forward) /
02(Enable for reverse) 00
00(Trip history clear) / 01(Parameter initialization) / 02(Trip history
clear and parameter initialization) 00
00
1.0
1.0
00
00
01
0.00
00
00
0.
0.0
0.
0.0
0.
0.0
15.00
1.00
0.
06
00
180
60
0.50
3.0
02
1.0
00
00
0.0
00
00
00
360/720
00
3000
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Rated
current
Rated
current
01
Rated
current*
1.20
01
01
00
00
-FE(CE)
Code Name Default Setting
-FU2(UL)
Run-time
Setting
Run-time Data Edit
(Enabled at b031)
Description
= Allowed
= Not permitted
[ ]
b084 Initialization mode
Rated
current*
1.10