English
(5)1 Without touching the trigger, depress the push lever against the workpiece.
Pull the trigger.
THE NAILER MUST OPERATE.
2Remove the finger from the trigger.
Nailer operation will end (the driver blade will return to the top).
(6)Set the switching device to the downward position (CONTACT ACTUATION MECHANISM).
(Set the switching device to the downward position completely as shown in the diagram. Otherwise, it will not operate properly.)
Switching Device
Downward position
With the Nailer off the workpiece, pull the trigger.
Depress the push lever against the workpiece.
THE NAILER MUST OPERATE.
(7)If no abnormal operation is observed, you may load nails in the Nailer.
Drive nails into the workpiece that is the same type to be used in the actual application.
THE NAILER MUST OPERATE PROPERLY.
WARNING
● Do not exceed 120 psi (8.3 bar 8.5 kgf/ cm2).
Adjust the air pressure at recommended operating pressure 70 – 120 psi (4.9 – 8.3 bar 5 – 8.5 kgf/cm2) according to the length of nails and the hardness of workpiece.
The correct air pressure is the lowest pressure which will do the job. Using the Nailer at a higher than required air pressure unnecessarily over stresses the Nailer.
LOADING NAILSWARNING
●When loading nails into Nailer,
1)do not pull trigger;
2)do not depress push lever; and
3)keep Nailer pointed downward.
(1)Insert nail strip into the back of the magazine.
Magazine
14