English
3Stop turning the adjuster when a suitable
position is reached for a nailing test.
4Connect the air hose.
ALWAYS WEAR EYE PROTECTOR. Perform a nailing test.
5DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
MAINTENANCE
NOTE:
The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer.
Some illustrations in this Manual may show details or attachments that differ from those on your own Nailer.
MAINTENANCE AND
INSPECTION
Read section titled “SAFETY” (pages 4 – 7).
WARNING
●Disconnect air hose and remove all nails from Nailer when:
1)doing maintenance and inspection; and
2)clearing a jam.
1.Inspecting the magazine
1DISCONNECT AIR HOSE.
2Clean the magazine. Remove paper chips or wooden chips which may have accumulated in the magazine. Lubricate it with Hitachi pneumatic tool lubricant.
CAUTION
●Check that the nail feeder slides smoothly by pulling it with finger.
If not smooth, nails can be driven at an
irregular angle and hurt someone.
2.Storing
When not in use for an extended period, apply a thin coat of the lubricant to the steel parts to avoid rust.
Do not store the Nailer in a cold weather environment.
Keep the Nailer in a warm area.
When not in use, the Nailer should be stored in a warm and dry place.
Keep out of reach children.
3.WARNING LABEL
Change the WARNING LABEL if missing or damaged.
A new WARNING LABEL is available from a Hitachi authorized service center.