OPTIONAL ACCESSORIES

... sold separately

￿Sequential Trip Mechanism Kit (Code No. 878226) (Single Shot Parts)

￿Pneumatic Tool Lubricant

1 oz. (30 cc) oil feeder

(Code No. 877153)

4 oz. (120 cc) oil feeder

(Code No. 874042)

1 quart (1 ltr) can

(Code No. 876212)

NOTE: Accessories are subject to change without any obligation on the part of HITACHI.

APPLICATIONS

￿Installation of asphalt roofing shingles in building contrcution.

￿Installation of insulation boards in building construction.

BEFORE OPERATION

Read section titled “SAFETY” (pages 4 – 7).

Make sure of the followings before operation.

WORKING ENVIRONMENT

WARNING

￿No flammable gas, liquid or other flammable objects at worksite.

￿Clear the area of children or unauthorized personnel.

AIR SUPPLY

DANGER

￿ NEVER use oxygen or other bottled gases. Explosion may occur.

￿Moisture or oil in the air compressor may accelerate wear and corrosion in the Nailer.

Drain daily.

2. Filter-Regulator-Lubricator

￿Use a regulator with a pressure range of 0 – 120 psi (0 – 8.3 bar 0 – 8.5 kgf/cm2).

￿Filter-regulator-lubricator units supply an optimum condition for the Nailer and extend the Nailer life. These units should always be used.

Filter ............. The filter removes moisture and dirt mixed in compressed air.

Drain daily unless fitted with an automatic drain.

Keep the filter clean by regular maintenance.

Regulator ..... The regulator controls the operating pressure for safe operation of the Nailer. Inspect the regulator before operation to be sure it operates properly.

Lubricator .... The lubricator supplies an oil mist to the Nailer.

Inspect the lubricator before operation to be sure the supply of lubricant is adequate.

Use Hitachi pneumatic tool lubricant.

Regulator

Nailer side Compressor side

Filter

Lubricator

3. Air hose

Air hose must have a minimum working pressure rating of 150 psi (10.4 bar 10.6 kgf/cm2) or 150% of the maximum pressure produced in the system, whichever is higher.

4. Hose coupling

￿The Nailer can be installed as follows: Remove the dust cap placed at the air inlet. Install a 3/8 NPT male plug at the air inlet.

Dust cap

WARNING

￿Never connect Nailer to pressure which potentially exceeds 200 psi (13.7 bar 14 kgf/cm2).

￿Never use non relieving coupler on Nailer.

1.Power source

￿Use only clean, dry, regulated compressed air as a power source for this Nailer.

￿Air compressors used to supply compressed air to this Nailer must comply with the requirements of the latest version of ANSI Standard B 19.3 “Safety Standard For Compressors For Process Industries.”

3/8 NPT male plug

￿A female coupler must be on the air hose.

The hose coupling (male plug-female coupler) must remove all pressure from the Nailer when disconnected.

Never use a non relieving coupler on the Nailer.

— 10 —