5-3. Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

Remedy

 

 

No weld output; unit completely

Place line disconnect device in On position (see Section 3-12).

inoperative; pilot light PL1 off.

 

 

 

 

 

 

 

 

 

Check for open line fuse(s), and replace if open (see Section 3-12).

 

 

 

 

 

 

 

Check for proper input power connections (see Section 3-12).

 

 

 

 

 

 

 

Check for proper jumper link position (see Section 3-12).

 

 

 

 

 

 

 

Check fuse F1, and replace if necessary (see Section 5-2).

 

 

No weld output; pilot light PL1 on.

Unit overheated. Allow unit to cool with fan On (see Section 3-2).

 

 

 

 

 

 

 

If using remote control, place Output (Contactor) switch in Remote 14 position, and connect remote

 

 

 

control (see Sections 3-9 and 3-10). If remote is not being used, place switch in On position (see

 

 

 

Section 4-1).

 

 

 

 

 

 

 

Check, repair, or replace remote control.

 

 

Limited weld output and low

Check position of Remote Amperage/Voltage Control switch (see Section 4-1).

open-circuit voltage.

 

 

 

 

 

 

 

 

 

Check for open line fuse(s), and replace if open (see Section 3-12).

 

 

 

 

 

 

 

Check for proper input power connections (see Section 3-12).

 

 

 

 

 

 

 

Check for proper jumper link position (see Section 3-12).

 

 

 

 

 

 

 

Clean and tighten all weld output connections.

 

 

Unit provides only maximum or

Have Factory Authorized Service Agent check control board PC1 and hall device HD1.

minimum weld output.

 

 

 

 

 

 

 

 

 

Check position of Remote Amperage/Voltage Control switch (see Section 4-1).

 

 

Erratic or improper weld output.

Use proper size and type of weld cable (see Section 3-8).

 

 

 

 

 

 

 

Clean and tighten all weld connections.

 

 

 

 

 

 

 

Check wire feeder installation according to Owner’s Manual.

 

 

 

 

 

 

 

Check position of Process selector switch (see Section 4-1).

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check control board PC1 and hall device HD1.

 

 

No 115 volts ac output at duplex recep-

Reset circuit breaker CB1 (see Section 3-7).

tacle, Remote 14 receptacle,

 

 

or terminal strip 1T.

 

 

 

 

No 24 volts ac output at Remote 14 re-

Reset circuit breaker CB2 (see Section 3-7).

ceptacle or terminal strip 1T.

 

 

 

 

Fan not operating. Note: fan only runs

Check for and remove anything blocking fan movement.

when cooling is necessary.

 

 

 

 

 

 

 

 

 

Have Factory Authorized Service Agent check fan motor.

 

 

Wandering arc; poor control of arc

Reduce gas flow rate.

direction.

 

 

 

 

 

 

 

 

 

Select proper size tungsten.

 

 

 

 

 

 

 

Properly prepare tungsten.

 

 

Tungsten electrode oxidizing and not

Shield weld zone from drafts.

remaining bright after conclusion of

 

 

weld.

 

 

 

 

 

 

 

 

 

Increase postflow time.

 

 

 

 

 

 

 

Check and tighten all gas fittings.

 

 

 

 

 

 

 

Properly prepare tungsten.

 

 

 

 

 

 

 

Check for water in torch, and repair torch if necessary. See torch Owner’s Manual.

 

 

Digital meter not working properly.

Have Factory Authorized Service Agent check control board PC1 and connections, and replace if

 

 

 

necessary.

 

 

 

 

 