Hobart H600 manual Electrical Connections, Check Rotation Three-Phase Machines Only

Models: H600

1 16
Download 16 pages 45.27 Kb
Page 5
Image 5
ELECTRICAL CONNECTIONS

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTION OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.

ELECTRICAL DATA

Model

Volts / Hz / Ph

Rated

Circuit Size

Fuse Size *

60°C Copper

Circuit Size

Circuit Breaker **

60°C Copper

Amps

(Amps)

(Amps)

Wire Size

(Amps)

(Amps)

Wire Size

 

 

 

 

 

 

 

 

 

 

 

H600

115 / 60 / 1

19.0

25

25

10

30

30

10

H600

200 / 60 / 1

10.9

15

15

14

20

20

12

H600

230 / 60 / 1

9.5

15

15

14

15

15

14

H600

200 / 60 / 3

5.8

15

10

14

15

10

14

H600

230 / 60 / 3

5.0

15

6

14

15

10

14

H600

460 / 60 / 3

2.5

15

3

14

15

6

14

 

 

 

 

 

 

 

 

 

H600 ‡

200 / 60 / 1

14.3

20

20

12

20

20

12

H600 ‡

230 / 60 / 1

12.9

20

20

12

20

20

12

H600 ‡

200 / 60 / 3

9.2

15

15

14

20

20

12

H600 ‡

230 / 60 / 3

8.4

15

10

14

20

20

12

 

 

 

 

 

 

 

 

 

L800

200 / 60 / 1

12.7

20

20

12

20

20

12

L800

230 / 60 / 1

11.0

15

15

14

20

20

12

L800

200 / 60 / 3

6.5

15

10

14

15

15

14

L800

230 / 60 / 3

5.6

15

6

14

15

10

14

L800

460 / 60 / 3

2.8

15

3

14

15

6

14

 

 

 

 

 

 

 

 

 

L800 ‡

200 / 60 / 1

16.1

25

25

10

30

30

10

L800 ‡

230 / 60 / 1

14.4

20

20

12

25

25

10

L800 ‡

200 / 60 / 3

9.9

15

15

14

20

20

12

L800 ‡

230 / 60 / 3

9.0

15

15

14

20

20

12

 

 

 

 

 

 

 

 

 

‡ Power Bowl Lift

 

 

* Dual Element

 

 

** Inverse Time

 

 

 

Time-Delay Fuse

 

Circuit Breaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 1993 Edition.

A hole for 34" trade size conduit is located at the top of the pedestal. Make electrical connections per the wiring diagram located on the inside of the Top Cover.

Check Rotation (Three-Phase Machines Only)

Three-phase machines must be connected so the planetary rotates in the direction of the arrow on the Drip Cup. To check rotation:

Set the gear shift lever on 1.

Apply power to the mixer, set the Electro-Mechanical Timer on HOLD; or, if equipped with a Programmable Timer Controller, set it on [ -- : -- ]. With the Bowl Support all the way up, momentarily run the machine by pushing the START and then STOP buttons.

If rotation is incorrect, DISCONNECT ELECTRICAL POWER SUPPLY and interchange any two of the incoming power supply leads.

– 5 –

Page 5
Image 5
Hobart H600 manual Electrical Connections, Check Rotation Three-Phase Machines Only