Lincoln 1100ADVSVC Troubleshooting Guide / Gas Ovens, Symptom, Possible Cause, Evaluation

Models: 1117-000-A 1100ADVSVC

1 36
Download 36 pages 40.03 Kb
Page 8
Image 8

TROUBLESHOOTING GUIDE / GAS OVENS

 

MODEL 1116-000-A

NATURAL GAS

120 VAC

60 HZ

1 PHASE

 

MODEL 1117-000-A

LP GAS

 

120 VAC

60 HZ

1 PHASE

 

 

 

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

EVALUATION

 

 

 

 

Oven fan will not run

Incoming Power Supply

Check breakers, reset it required. Check power plug

 

 

 

 

to be sure it is firmly in receptacle. Measure

 

 

 

 

incoming power/call power company if needed.

 

 

Fuse, 10 Amp

 

Check, replace if necessary.

 

 

 

 

Fuse Holder

 

Check, replace if necessary.

 

 

 

 

Hi Limit Thermostat-Control

Check for voltage on both sides of the switch.

 

 

Box

 

Terminals are normally closed. If open, reset and

 

 

 

 

test oven for proper operation. If thermostat will not

 

 

 

 

hold and control box temperature is not exceeding

 

 

 

 

140°F (60°), replace thermostat.

 

 

Main Fan Switch

 

Check continuity between switch terminals.

 

 

Main Fan Motor

 

Check for opens, shorts, or grounds. WITH POWER

 

 

 

 

OFF turn fan blade to check for locked rotor.

 

 

Capacitor

 

Check for shorts or grounds.

 

 

 

 

 

 

WARNING: Capacitor has a stored charge,

 

 

 

 

discharge before testing.

 

 

 

No control box cooling

Incoming Power

 

Check main circuit breakers, reset if required, call

 

 

 

 

power company if needed.

 

 

 

 

Main Fan Switch

 

Check continuity between switch terminals

 

 

Cooling Fan

 

120 VAC should now be at the fan motor. If voltage

 

 

 

 

is present, check motors for shorts or opens. WITH

 

 

 

 

POWER OFF: Check for locked rotor.

 

No automatic control

Incoming Power Supply

Check circuit breakers,

 

 

 

box cooling

 

 

reset if required. Call the power company if needed.

 

 

Cooling Fan Thermostat

Check the cooling fan thermostat. (Thermostat

 

 

 

 

closes at 120°F and opens at 100°F). With the

 

 

 

 

cooling fan thermostat preheated, check for

 

 

 

 

continuity. If switch is open, replace.

 

 

Cooling Fan

 

120 VAC should be at the motor. If voltage is

 

 

 

 

present, check motor for shorts, opens, or grounds.

 

 

 

 

WITH POWER OFF: check for locked rotor.

 

Oven will not heat

Gas Supply

 

Check for adequate gas supply and closed manual

 

 

 

 

gas shut offs. Also, check flexible gas line

 

 

 

 

connection.

 

 

 

 

 

Main Fan

 

If not operating, refer to "Oven fan will not run".

 

 

High Limit Oven Cavity

Terminals are normally closed. If

 

 

Thermostat

 

open, push in reset button and retest. If thermostat

 

 

 

 

will not hold for maximum oven temperature, and

 

 

 

 

oven is not exceeding temperature dial setting,

 

 

 

 

check for proper location of capillary bulb in its

 

 

 

 

spring holder. If above checks okay, replace hi-limit

 

 

 

 

thermostat.

 

 

 

 

 

Centrifugal Switch

Check for 120 VAC at lead #9

 

 

 

 

of Main Fan Motor

(located at 6 pin connector in raceway near the main

 

 

 

 

fan motor) to neutral. If no voltage is present, and

 

 

 

 

motor is running, replace motor.

8

 

 

 

Impinger II – Advantage Service Manual - Domestic

Page 8
Image 8
Lincoln 1100ADVSVC, 1117-000-A service manual Troubleshooting Guide / Gas Ovens, Symptom, Possible Cause, Evaluation