Temp. display inoperative

Display Transformer

Measure the transformer primary for a nominal 120

 

 

VAC input, if voltage is not present, trace wiring back

 

 

to the oven power source. Measure the secondary

 

 

output, which will normally be 12-15 VAC. Voltage

 

 

across terminals 1 and 3 on the time/temp. display

 

 

should read 12-15 VAC. Terminals 1-2 and 2-3

 

 

should be 1/2 the voltage reading to 1-3. If the

 

 

above secondary readings are not achieved, replace

 

 

transformer.

 

Temp. Display

If proper voltage is present at terminals 1, 2, and 3

 

 

on temperature display, but the display is not lighted,

 

 

recheck all connections for tightness. If temperature

 

 

display is still not operating, replace the temperature

 

 

display.

Temp. Display inaccurate,

Thermocouple

Place the thermocouple of a pyrometer into the

erratic or inoperative

 

center of the top finger. Be sure the tip of the

 

 

thermocouple is not touching metal, it must sense air

 

 

temperature only. The pyrometer will indicate oven

 

 

temperature. Measure DC millivolts of thermocouple

 

 

at the temperature display. See thermocouple chart

 

 

on page 19 for proper readings. Replace

 

 

thermocouple if proper readings are not achieved. If

 

 

readings are correct on the thermocouple, replace

 

 

temperature display.