Lincoln 1117-000-A, 1100ADVSVC Burner Transformer - Replacement, Thermocouple - Replacement

Models: 1117-000-A 1100ADVSVC

1 36
Download 36 pages 40.03 Kb
Page 19
Image 19
BURNER TRANSFORMER - REPLACEMENT

BURNER TRANSFORMER - REPLACEMENT

1.Shut power off at main breaker.

2.Remove control panel top and front cover.

3.Remove two (2) wires on primary side, note color and location.

4.Remove two (2) wires on secondary side, note color and location.

5.Remove two (2) screws from transformer base and replace assembly.

6.Reinstall in reverse order and check system operation.

THERMOCOUPLE - REPLACEMENT

1.Shut off power at main breaker.

2.Remove control panel top and front cover.

3.Slide thermocouple out of oven chamber.

NOTE: Remove conveyor and bottom finger assembly to aid in removal and installation of thermocouple.

4.Remove two (2) wires from temperature control. Make note of wire numbers or color and location for reinstallation.

5.Reassemble in reverse order making sure the metal end on the thermocouple is securely held in the wire form in the oven chamber.

THERMOCOUPLE MEASUREMENT CHART:

INFORMATION:

When two wires composed of dissimilar metals are joined together and one of the ends is heated, a continuous current flow is generated. We use an iron constant (Type J) thermocouple. The iron wire increases the number of dissimilar junctions in the circuit.

It is possible to check a thermocouple with a properly calibrated D.C. millivolt meter. At 32°F, the millivolt reading should be 0.00. This can be checked by inserting the thermocouple into an ice bath.

The millivolt reading at 72°F should be 1.134.

When using the following chart, the temperature at the terminal connections must be noted. This temperature is called the Junction Temperature.

The following chart lists the thermocouple millivolt readings from 200°F to 600°F.

EXPLANATION: The junction temperature is the ambient air temperature where the thermocouple fastens to the electronic temperature control.

 

 

 

O

V

E

N

 

T

E

M

P

 

 

 

200°F

250°F

300°F

325°F

350°F

400°F

425°F

450°F

500°F

550°F

600°F

J

90°F

3.26

4.77

6.30

7.06

7.83

9.37

10.14

10.91

12.46

14.00

15.53

U

88°F

3.32

4.83

6.36

7.12

7.89

9.43

10.20

10.97

12.51

14.05

15.59

N

86°F

3.37

4.88

6.41

7.17

7.94

9.49

10.26

11.03

12.57

14.11

15.65

C

84°F

3.43

4.94

6.47

7.23

8.00

9.54

10.31

11.09

12.63

14.19

15.71

T

82°F

3.49

5.00

6.53

7.29

8.06

9.60

10.37

11.14

12.69

14.23

15.76

I

80°F

3.55

5.06

6.59

7.35

8.12

9.66

10.43

11.20

12.74

14.28

15.82

O

78°F

3.60

5.11

6.64

7.40

8.17

9.72

10.49

11.26

12.80

14.34

15.86

N

76°F

3.66

5.17

6.70

7.46

8.23

9.77

10.55

11.32

12.86

14.40

15.94

 

75°F

3.69

5.20

6.73

7.49

5.26

9.80

10.57

11.35

12.89

14.43

15.97

 

74°F

3.72

5.23

6.76

7.52

8.29

9.83

10.60

11.37

12.92

14.46

15.99

 

72°F

3.78

5.29

6.82

7.58

8.35

9.89

10.66

11.43

12.97

14.51

16.05

T

70°F

3.83

5.34

6.87

7.63

8.40

9.95

10.72

11.49

13.03

14.57

16.11

E

68°F

3.89

5.40

6.93

7.69

8.46

10.00

10.78

11.55

13.09

14.63

16.17

M

66°F

3.95

5.46

6.99

7.75

8.52

10.06

10.83

11.61

13.15

14.69

16.23

P

64°F

4.01

5.52

7.05

7.81

8.58

10.12

10.89

11.66

13.20

14.74

16.28

 

62°F

4.06

5.57

7.10

7.86

8.63

10.18

10.95

11.72

13.26

14.80

16.34

 

60°F

4.12

5.63

7.16

7.92

8.69

10.24

11.01

11.78

13.32

14.86

16.40

Impinger II –Advantage Service Manual - Domestic

19

Page 19
Image 19
Lincoln 1117-000-A Burner Transformer - Replacement, Thermocouple - Replacement, Thermocouple Measurement Chart