OPERATION

OPERATION

The booster heater is designed to deliver 180°F water, up to the gallons per minute and gallons per hour ratings specified in the table on page 4, depending on the incoming water temperature and Booster Heater model and its input BTU/Hr.

Provided the necessary power, water, gas, and vent connections are completed, a STAND ALONE unit is started by the activation of the On / Off Switch located on the front (Fig. 9). Provided the necessary power, water, gas, and vent connections are completed, the DISHWASHER ACTIVATED unit will be On when the dishwasher power switch is On. The Green indicator light is lit and the circulator pump turns on when power to the booster heater is On. The blower motor will start after about 6 seconds if the thermostat calls for heat.

Provided that the operating and safety controls including any vent switches are closed and that the thermostat is calling for heat, the Amber indicator light is lit. The blower turns on for about 10 seconds, providing clean air in the combustion chamber. Then the gas valve opens and the hot surface ignitor heats up for four seconds. With ignition, the flame sensor will detect that the burner flame has been established. If the burner flame is not sensed within a few seconds, the circuit repeats the process from for a total of three trial ignitions before the gas valve shuts off and requires reset.

To reset the ignition safety shutoff, momentarily turn the power switch off and then back on. If no power switch is present, turn the dishwasher off for one minute and then turn the dishwasher back on. When the water temperature exceeds the setting of the operating temperature control (thermostat board assembly), the burner will shut off until the next call for heat. The operating temperature control (thermostat board assembly) is factory set at 185°F.

On STAND ALONE units, the circulator pump will stay on as long as the On / Off Switch is on. On DISHWASHER ACTIVATED units, pump will stay on as long as the dishwasher is on. The blower is on when the thermostat is calling for heat and for 30 seconds after it is satisfied.

Flame

Observation

Port

Amber Indicator Light –

Heat is being demanded.

Green Indicator Light –

The Booster Heater has power.

On / Off Switch –

Present only on Stand Alone Units.

NOTE:

Dishwasher Activated

units do not have an On/Off Switch The booster heater starts when the dishwasher power is on.

PL-53172

Fig. 9

– 16 –

Page 16
Image 16
Hobart IB235 ML-110861, IB290 ML-110862, IB57 ML-110898, IB140 ML-110899 manual Operation

FAQ

How do I start the booster heater?

The standalone unit is started by activating the On / Off Switch, while the dishwasher activated unit will turn on when the dishwasher power switch is on.

What does the green indicator light indicate?

The green indicator light means that the booster heater has power.

What should I do if the ignition safety shut-off is activated?

To reset the ignition safety shut-off, momentarily turn the power switch off and then back on, or turn the dishwasher off for one minute and then turn it back on if no power switch is present.