Installation, Operation, and Care of

Installation, Operation, and Care of

INFRARED BOOSTER GAS WATER HEATERS

SAVE THESE INSTRUCTIONS

GENERAL

The Infrared Booster Gas Water Heaters (available for natural gas or propane) provide 180°F rinse water for commercial dishwashing machines. Health codes and NSF permit 180°F (minimum temperature) water to be used as a sanitizing rinse for utensils and dishware used in restaurants and food-serving operations. Water enters the gas booster water heater at the inlet water connection, circulates through the gas heat exchanger and stainless steel tank, and constantly maintains the 180°F minimum water temperature at the outlet connection. The table, Delivery Rates @ 180°F, indicates the maximum amount of hot water that can be delivered by the various Booster Heater models, depending on the incoming water temperature.

Rinse water volume requirements for various commercial dishwasher models and operating rates are available from your authorized Hobart dealer.

Model

Input (Btu/hr)

Input (Btu/hr)

Tank Capacity

Width x Height x Depth (Inches)

Natural Gas

Propane

(U.S. Gallons)

 

 

 

 

 

 

 

IB57

57,000

57,000

9.5

25.375 x 30.125 x 19.50

IB140

140,000

140,000

9.5

28.375 x 32.125 x 22.25

IB235

235,000

235,000

17.0

36.875 x 32.125 x 22.25

IB290

290,000

280,000

17.0

36.875 x 32.125 x 22.25

DELIVERY RATES @ 180° F (assuming 80% efficiency)

Model

Input

Rate

Incoming Water Temperature

 

(Btu/hr)

 

 

 

 

 

 

110° F

120° F

130° F

140° F

150° F

 

 

 

IB57

57,000

Gallons per Minute

1.30

1.52

1.82

2.28

3.04

Natural or

 

 

 

 

 

 

Gallons per Hour

78

91

109

137

182

 

Propane

 

 

 

 

 

 

 

 

IB140

140,000

Gallons per Minute

3.20

3.73

4.48

5.60

7.46

Natural or

 

 

 

 

 

 

Gallons per Hour

192

224

268

336

448

 

Propane

IB235

235,000

Gallons per Minute

5.37

6.27

7.52

9.40

12.54

Natural or

 

 

 

 

 

 

Gallons per Hour

322

376

451

564

752

 

Propane

 

 

 

 

 

 

 

 

 

290,000

Gallons per Minute

6.63

7.74

9.28

11.60

15.47

IB290

Natural

Gallons per Hour

398

464

557

696

928

280,000

Gallons per Minute

6.40

7.47

8.96

11.20

14.94

 

 

Propane

Gallons per Hour

384

448

538

672

896

NOTE: For altitudes above 5000 feet, contact Hobart Product Service, phone (937) 332-2525, Warewash Technical Support.

– 4 –

Page 4
Image 4
Hobart IB235 ML-110861, IB290 ML-110862 Installation, Operation, and Care of, Infrared Booster Gas Water Heaters, General

FAQ

What temperature does the gas water heater maintain?

The gas water heater maintains a minimum water temperature of 180F at the outlet connection.

What are the delivery rates at 180F for the different models?

The delivery rates at 180F for the IB57, IB140, IB235, and IB290 models are provided in the table.

How can I determine the rinse water volume requirements for my commercial dishwasher?

You can obtain rinse water volume requirements for various commercial dishwasher models from your authorized Hobart dealer.