5-6. Selecting A Location And Connecting Input Power

18 in (457 mm) of space for airflow

Y Special installation may be required where gasoline or volatile liquids are present − see NEC Article 511 or CEC

 

 

 

 

 

Section 20.

 

 

 

 

 

 

Y Installation must meet all Na-

 

 

 

 

 

tional and Local Codes −

 

 

 

 

 

have only qualified persons

 

 

 

 

 

make this installation.

 

 

 

 

 

Y Disconnect and lockout/tag-

 

 

 

 

 

out input power before con-

 

 

 

 

 

necting

input

conductors

 

 

 

 

 

from unit.

 

 

 

 

 

 

Y Always

connect green

or

 

 

 

 

 

green/yellow conductor

to

 

 

 

 

 

supply grounding terminal

Y Do not move or operate

 

 

 

first, and never to a line

ter-

unit where it could tip.

 

 

 

minal.

 

 

 

 

 

 

 

1

Rating Label

 

 

 

=GND/PE Earth Ground

 

Supply correct input power.

 

 

1

 

 

2

Black And White Input

 

 

 

 

 

Conductor (L1 And L2)

 

 

6

 

 

3

Green Or Green/Yellow

 

 

 

 

 

Grounding Conductor

 

 

 

 

 

4

Input Power Cord.

 

 

 

9

 

5

Disconnect Device (switch

 

 

 

 

 

shown in the OFF position)

 

 

 

 

 

 

 

 

 

6

Disconnect Device Grounding

 

 

5

 

 

Terminal

 

 

 

 

 

 

7

Disconnect Device Line

 

 

 

 

 

 

 

 

7

 

 

Terminals

 

 

 

 

 

Connect

green or

green/yellow

 

 

L1

 

 

 

2

grounding conductor to disconnect

 

 

 

 

 

L2

device grounding terminal first.

 

 

 

 

 

 

3

 

 

Connect input conductors L1 and

 

 

 

L2 to disconnect device line

 

 

 

 

 

4

 

 

terminals.

 

 

 

 

 

 

 

 

 

 

 

 

 

1

10

 

 

8

Receptacle (NEMA 6-50R)

 

 

 

Connect receptacle as shown.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Over-Current Protection

 

 

 

 

 

Select type and size of over-current

 

 

 

 

protection using Section 5-7(fused

 

 

 

 

disconnect switch shown).

 

 

 

 

 

Close and secure door on disconnect

 

 

 

 

device.

Remove

lockout/tagout

 

8

 

 

device, and place switch in the On

 

 

 

 

position.

 

 

 

 

 

L2

L1

 

10

Plug (NEMA 6-50P)

 

 

 

 

 

 

 

 

 

Connect plug to receptacle.

230 VAC, 1

ssb2.2* 1/94 − 804 687-A

OM-227 978 Page 14