OM-478 Page 19
ether1 7/96 ST-153 382-A / ST-180 933
Stop engine.
Improper handling or expo-
sure to ether can harm your
health. Follow manufactur-
ers safety instructions on
cylinder.
Do not use Ether Starting Aid
while engine is running.
Open side door(s).
1 Ether Cylinder
2 Nozzle
Remove cover and clean cylinder
nozzle.
3 Clamp
4 Fitting
5 Cap
6 Valve
Remove cap and clean fitting.
Install cylinder on fitting. Tighten
clamp.
After installing cylinder, wait at
least 10 minutes before using
to let ether particles settle and
prevent atomizer plugging.
Put cap on fitting when cylinder is
removed.
1
2
3
4
6
5

4-7. Installing Ether Cylinder (Optional Ether Starting Aid)

4-8. Remote 14 Receptacle RC3 Information

Socket* Socket Information

A24 volts ac. Protected by circuit
breaker CB4.
AJ
BKI
CLNH
BContact closure to A completes 24
volts ac contactor control circuit.
DMG
EFI115 volts ac. Protected by circuit
breaker CB3.
JContact closure to I completes 115
volts ac contactor control circuit.
OR
GCircuit common for 24 and 115
volts ac circuits.
OR
C 0 to +10 volts dc output to remote
control from min to max of Amper-
age/Voltage control R1.
A/V DRemote control circuit common.
A/V E0 to +10 volts dc input command
signal from remote control.
Ref. ST-800 729-A K Chassis common.
*The remaining sockets are not used.