OM-478 Page 20
4-9. Terminal Strip 3T Connections
Ref. ST-121 578-F / Ref. S-184 781-A
Stop engine.
If remote control plug does not fit in
receptacle RC3, wire cord directly
to terminal strip 3T.
Do not connect to Remote 14
receptacle RC3 and terminal
strip 3T at the same time. Use
only one remote control
method.
Open lower front door.
1 Terminal Strip 3T
Connect leads to 3T using terminal
information shown in Section 4-8.
Reinstall cover. Close door.
Tools Needed:
1
4-10. Air Compressor Connections
ST-800 727 / Ref. ST-121 578-F
Air compressor operates whenever
engine is running.
1 1/2 in NPT Air Compressor
Fitting
Connect quick-disconnect air hose
to fitting (hose not supplied).
2 Air Shutoff Valve
Be sure valve is in open position
when using air compressor.
Open Position
Closed Position
2
1