Hobart Welding Products OM-928 specifications Installation, Specifications For Power Source

Models: OM-928

1 32
Download 32 pages 5.1 Kb
Page 13
Image 13

SECTION 2 – INSTALLATION

2-1. Specifications For Power Source

 

 

 

 

 

 

 

 

Max**

Primary

Primary

Primary Service

Secondary

Secondary

KW

KVA

Power

OCV

Volts

Amperes

(Recommended)

Volts (DC)

Amperes

Factor

(DC)

 

 

 

 

 

 

 

 

 

120

20.32 (0.25*)

20A

110

12

2.01

2.44

0.82

353

 

 

 

 

 

 

 

 

 

*While idling

 

 

 

 

 

 

 

 

**10% High line condition

2-2. Specifications For Torch

Air-cooled torch for plasma arc cutting (PAC)

35% duty cycle

Gas flow/pressure: 1 SCFM (28.3 L/min) at 50 PSI (345 kPa)

Safety interlock devices shut down power source

Safety trigger guard

Cutting capacity: see Section 2-1

2-3. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can cut at rated load without overheating.

If unit overheats, thermostat(s) opens, output stops, Temperature trouble light goes On, and cooling fan runs. Wait fifteen minutes for unit to cool or temperature light to go off. Reduce amperage or duty cycle before cutting or gouging.

Y Exceeding duty cycle can damage unit and void warranty.

3-1/2 Minutes Cutting

6-1/2 Minutes Resting

Overheating

0

15

Minutes

duty1 4/95 – 802 588-A