7-2. Optional Generator Power Receptacles

Notes

YIf unit does not have GFCI re- ceptacles, use GFCI- protected extension cord.

Combined output of all receptacles limited to 10 kVA/kW rating of the generator.

GFCI Receptacle Option

1 120 V 20 A AC GFCI Recep- tacles GFCI2 and GFCI3

GFCI2 and GFCI3 supply 60 Hz

1 single-phase power at weld/power speed. Maximum output from GFCI2 or GFCI3 is 2.4 kVA/kW. Cir-

cuit protection is the same as stan- dard receptacles.

If a ground fault is detected, the GFCI Reset button pops out and the circuit opens to disconnect the faulty equipment. Check for damaged tools, cords, plugs, etc. connected to the receptacle. Press button to reset receptacle and resume operation.

.At least once a month, run

engine at weld/power speed and press Test button to verify GFCI is working properly.