Home Automation 10A11-1 manual Controller Setup, Operation, OmniLT Installation, Page

Models: 10A11-1

1 4
Download 4 pages 12.4 Kb
Page 3
Image 3
Figure 2 - OmniLT Installation

Figure 2 - OmniLT Installation

Figure 3 - Omni II, OmniPro II, Lumina, and Lumina Pro Installation

CONTROLLER SETUP

When using a Model 10A11-1, Rev C for two-way communication with a central station, the Two-Way Voice option must be enabled. From the Installer Setup menu, select the 3 (DCM) key. Press the down arrow (Ø) key until you reach the Two-Way Audio option:

TWO-WAY AUDIO:

0

0=NO 1=YES

Press 1 (YES), and then press ' # ' to enable two-way audio communication.

When using a Model 10A11-1, Rev C to announce alarms, the Announce Alarms option must be enabled. To enable this option, from the Setup menu press the 6 (MISC) key. Press the down arrow (Ø) key to until you reach the Announce Alarms option:

ANNOUNCE ALARMS:

0

0=NO 1=YES

Press 1 (YES), and then press ' # ' to enable the system announce alarms.

OPERATION

The Two-Way Audio Module has two modes of audio communication:

1.Listen mode is used to listen to the premises from an inside, remote, or central station telephone. You cannot talk to anyone on premises in listen mode. Whenever the module is switched on, it is set to the listen mode.

2.Talk mode is used to talk to someone on-premises from an inside, remote, or central station telephone. You cannot listen to the premises while in the talk mode.

The mode can be changed between listen and talk by using the keys on a phone. When the module is switched on, a 90 second disconnect timer is started. If no tones are detected within 90 seconds, the module will be switched off. Each time a tone is received, the timer is reset.