Homelite UT903650 Before Operating the Unit, CHECKING/ADDING Lubricant, CHECKING/ADDING Fuel

Models: UT903650

1 60
Download 60 pages 36.23 Kb
Page 17
Image 17

OPERATION

BEFORE OPERATING THE UNIT

Only use OUTSIDE and far away from windows, doors, and vents.

NEVER use inside a home or garage, EVEN IF doors and windows are open.

Always position the generator on a flat firm surface.

CAUTION:

Attempting to start the engine before it has been properly filled with lubricant will result in equipment failure.

CHECKING/ADDING LUBRICANT

See Figure 8.

Engine lubricant has a major influence on engine perfor- mance and service life. For general, all-temperature use, SAE 10W-30 is recommended. Always use a 4-stroke motor lubricant that meets or exceeds the requirements for API service classification SJ.

NOTE:Non-detergent or 2-stroke engine lubricants will damage the engine and should not be used.

Unscrew the oil cap/dipstick and remove.

Wipe dipstick clean and re-seat in hole; do not re-thread.

Remove dipstick again and check lubricant level. Lubricant level should fall between the hatched areas on the dipstick.

If level is low, add engine lubricant until the fluid level rises to the upper portion of the dipstick.

Replace and secure the oil cap/dipstick.

CHECKING/ADDING FUEL

See Figure 9.

Remove the fuel cap.

Fill the fuel tank to 1 in. below the top of the fuel neck.

Replace and secure the fuel cap.

NOTE:  Always use unleaded gasoline with a pump octane rating of 86 or higher. Never use old, stale, or contaminated gasoline, and do not use an oil/gas mixture. Do not allow dirt or water into the fuel tank.

USING FUEL STABILIZER

Fuel gets old, oxidizes, and breaks down over time. Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow fuel stabilizer manufacturer’s directions for correct ratio of stabilizer to fuel.

Add stabilizer to fuel tank, then fill with gasoline following previous instructions.

NOTE:  Fuel stabilizer and gasoline can be mixed prior to filling the tank by using a gas can or other approved fuel container and shaking gently to combine.

Replace and secure the fuel tank cap.

Start and run the engine for at least 5 minutes to allow stabilizer to treat the entire fuel system.

OXYGENATED FUELS

DO NOT USE E85 FUEL. IT WILL VOID YOUR WARRANTY.

NOTE: Fuel system damage or performance problems re- sulting from the use of an oxygenated fuel containing more than the percentages of oxygenates stated below are not covered under warranty.

Ethanol. Gasoline containing up to 10% ethanol by volume (commonly referred to as E10) is acceptable. E85 is not.

CAUTION:

On a level surface with the engine off, check the lubricant level before each use of the generator.

STARTING THE ENGINE

See Figures 10 - 12.

NOTE:  If location of generator is not level, the unit may not start or may shut down during operation.

Unplug all loads from the generator.

Turn the fuel valve to the ON position.

Move the choke lever right to the START position.

NOTE:  If engine is warm or the temperature is above

50˚F, move the choke lever left to the RUN position.

Put the engine switch in the ON ( I ) position.

Pull the recoil starter grip until the engine runs (a maximum of 6 times).

NOTE:  Do not allow the grip to snap back after starting; return it gently to its original place.

Allow the engine to run for 30 seconds, then move the choke lever left to the RUN position.

Page 13 — English

Page 17
Image 17
Homelite UT903650 Before Operating the Unit, CHECKING/ADDING Lubricant, CHECKING/ADDING Fuel, Using Fuel Stabilizer

UT903650 specifications

The Homelite UT903650 is a versatile and powerful string trimmer that caters to both professional landscapers and DIY enthusiasts. Designed for optimal performance, this tool features a robust 25cc 2-cycle engine, which delivers ample power to tackle even the toughest grass and weeds. With its lightweight construction, the UT903650 ensures easy maneuverability, reducing user fatigue during extended use.

One of the standout features of the UT903650 is its Easy Start technology. This innovative system makes starting the engine a breezy affair, allowing users to get to work without the hassle often associated with traditional string trimmers. The trimmer is also equipped with a dual-line cutting system, which provides a wider cutting diameter, making it more efficient for clearing out larger areas in less time.

The trimmer's head features Auto Feed Spool technology, which automatically feeds the cutting line as needed. This eliminates the need for manual adjustments, ensuring consistent cutting performance, and reducing downtime. The inclusion of a rotating handle provides added flexibility, allowing for precise trimming and edging along flower beds and driveways.

For comfort during use, the UT903650 comes with an adjustable handle that caters to various user heights and preferences. This ergonomic design not only enhances comfort but also improves control over the trimmer. The lightweight design further adds to its user-friendliness, making it ideal for prolonged use without causing strain.

The Homelite UT903650 is also built with durability in mind. Its high-quality materials and reinforced structures allow it to withstand tough conditions, ensuring that it remains reliable season after season. Additionally, the trimmer meets stringent emission standards, making it an environmentally friendly choice for those who are conscious about their ecological footprint.

Overall, the Homelite UT903650 string trimmer is a robust, user-friendly tool packed with features that enhance its performance and ease of use. From professionals to homeowners looking for a reliable gardening tool, the UT903650 stands out as an excellent choice for maintaining a well-groomed lawn and garden. Whether tackling overgrown areas or performing routine maintenance, this trimmer is designed to deliver consistent results with efficiency and ease.