Honda Power Equipment EM1600X, EM1800X, EM2200X owner manual DC application

Models: EM1600X EM1800X, EM2200X

1 36
Download 36 pages 7.74 Kb
Page 15
Image 15
DC application

DC application

The DC terminals may be used for charging 12 volt automotive-type batteries only.

mBatteries produce explosive gases. Keep sparks, flames, and

cigarettes away. To prevent the possibility of creating a spark near the battery, connect charging cables first to the battery, then to the generator, and disconnect cables at the generator first.

CAUTION:

lDo not attempt to start an automobile engine while the generator is still

connected to the battery. The generator may be damaged.

lConnect the positive battery terminal to the positive generator terminal. Do not reverse the charging cables, or serious damage to the generator and/or battery may occur.

NOTE:

lThe DC terminals may be used while the AC power is in use.

lAn overloaded DC circuit will trip the DC circuit protector (push button

comes out). If this happens, wait a few minutes before pushing in the circuit protector to resume operation.

DC CIRCUIT BREAKER

POSITIVE TERMINAL (RED)

(BLACK)

13

Page 15
Image 15
Honda Power Equipment EM1600X, EM1800X, EM2200X owner manual DC application