Oil Alert System

Oil Alert System

Before the oil level in the crankcase can fall below a safe limit, the Oil Alert System will automatically shut off the engine. The Oil Alert Lamp will light when the recoil starter grip is pulled.

To restart, add enough recommended engine oil to bring the oil level to the upper level mark on the dipstick (See page 6), and restart the engine.

ENGINE

SWITCH

OIL ALERT

LAMPE

NOTE: The engine switch will remain in the ON position if the engine is stopped by the Oil Alert System.

High altitude operation

At high Altitude, the standard carburetor air-fuel mixture will be excessively rich. Performance will decrease, and fuel consumption will increase.

High altitude performance can be improved by installing a smaller diameter main fuel jet in the carburetor and readjusting the pilot screw. If you always operate the generator at altitudes higher than 6,000 feet above sea level, have your authorized Honda Generator dealer perform these carburetor modifications.

Even with suitable carburetor jetting, engine horsepower will decrease ap- proximately 3.5% for each 1,000 foot increase in altitude. The affect of altitude on horsepower will be greater than this if no carburetor modification is made.

CAUTION: Operation of the generator at an altitude lower than the car- buretor is jetted for may result in reduced performance, overheating, and serious engine damage caused by an excessively lean air/fuel mixture.