OPERATION
AC PARALLEL OPERATION
PARALLELOPERATION CABLE KIT
(optionalequipment)
OUTPUTINDICATOR
Before connecting an appliance to either generator, make sure that the
appliance is in good working order and that its electrical rating does
not exceed that of the receptacle.
During parallel operation, the Eco-Throttle switch should be in the
same position on both generators.
Connect the parallel operation cable kit between the two EU3000i
generators following the instructions supplied with the kit.
Start the engines (see page ) and make sure the output indicator
(green) on each generatorcomes on.
Most motorized appliances require more than their electrical rating for
startup. When an electric motor is started, the overload indicator (red)
may come on. This is normal if the overload indicator (red) goes off
within 9 seconds. If the overload indicator (red) stays on, consult your
generator dealer.
1.
2. 23